Literature DB >> 30782504

Spinal dural closure without suture: Minimizing the risk of CSF leakage with a flat non-penetrating titanium U-clip.

Francisco M Marin Laut1, Efraim A Gómez Cárdenas2, Jesús Riqué Dormido2, Nicolás Moliz Molina2, Jose A López López2.   

Abstract

BACKGROUND: The classic surgical spinal dural closure technique in surgery on intradural lesions is performed with continuous suture or loose stitches using 4-0 to 6-0 polypropylene monofilament or nylon suture. Dural closure with suture causes irritant damage to the dural/arachnoid interface. The penetrating suture causes new dural holes. Even the needle of the suture can cause harm to the patient and the surgeon. For these reasons, other non-penetrating techniques for dural closure have been sought.
OBJECTIVE: The purpose of this review was to show the efficacy of using the titanium clip (U-clip) (Ligaclip-MCA of Ethicon Endo-Surgery, LLC, Medical GmbH, Norderstedt, Germany) with a flat internal surface in spinal neurosurgical procedures, and to evaluate the effects of its use on post-operative magnetic resonance imaging (MRI).
METHODS: We performed a retrospective analysis of a cohort of 50 consecutive patients who underwent intradural spinal surgeries for intradural spinal lesions in the neurosurgery department of our institution between 2013 and 2018.
RESULTS: The mean follow-up period was 27 months. No patient developed a post-operative cerebrospinal fluid (CSF) dural-cutaneous fistula. CSF leakage was not observed in the control MRIs at 6 weeks.
CONCLUSIONS: We describe, for the first time, the use of this type of U-clip with a flat inner side. The non-penetrating titanium U-clip facilitates effective and rapid dural closure at all spinal levels due to its flat internal face when closed. The U-clips did not cause significant artefacts or distortions on the magnetic resonance imaging.
Copyright © 2019 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Anastomotic clips; Cierre dural espinal; Clip de anastomosis; Clips de titanio no penetrantes; Fístula postoperatoria del líquido cefalorraquídeo; Non-penetrating titanium clips; Postoperative cerebrospinal leakage; Spinal dural closure

Mesh:

Substances:

Year:  2019        PMID: 30782504     DOI: 10.1016/j.neucir.2018.12.002

Source DB:  PubMed          Journal:  Neurocirugia (Astur : Engl Ed)        ISSN: 2529-8496


  2 in total

1.  Factors Influencing Surgical Outcomes for Intradural Spinal Tumours: A Single-Centre Retrospective Cohort Study.

Authors:  Wai C Soon; Benjamin Fisher; Yasir A Chowdhury; James Hodson; Edward Fashola; Ofuchi Egbuji; Andraay Leung; Marcin Czyz; Navin Furtado; Jasmeet Dhir
Journal:  Cureus       Date:  2022-02-01

2.  Scar quality examination comparing titanium-coated suture material and non-coated suture material on flap donor sites in reconstructive surgery.

Authors:  Laura K Berninghausen; Georg Osterhoff; Stefan Langer; Lukas H Kohler
Journal:  BMC Surg       Date:  2020-11-03       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.