EchoScopy in scanning abdominal diseases; a prospective single center study.

Ana Paula Barreiros1, Yi Dong2, Andre Ignee2, Daniel Wastl3, Christoph F Dietrich4.   

Abstract

BACKGROUND AND AIMS: The introduction of a new type of small handheld ultrasound device brings greater portability and affordability in a different setting. The basic ultrasound approach with these handheld devices has been defined by European Federation of Societies of Ultrasound in Medicine and Biology (EFSUMB) as "EchoScopy". The current study aimed to assess the image quality, indications and limitations of a portable pocket "EchoScopy" performed first compared with a high-end ultrasound system (second) in abdominal diseases.
MATERIAL AND METHODS: Three hundred consecutive patients (158 males and 142 females, age 55±19 [18-96]) years) were included. The ultrasound examinations were performed firstly by an EchoScope (Vscan™ Dual Probe) and secondly with a high-end ultrasound system (HEUS, GE Logiq E9). Compared with the always excellent image quality using HEUS, the image quality of the EchoScope was graded as good, sufficient or non-sufficient.
RESULTS: Out of all 300 patients, 221 had focal lesions, 31 patients were found with diffuse pathological findings, 20 with ascites, 25 after liver puncture and 45 without any pathological findings. The image quality of the pocket device was considered as being good or sufficient to delineate the pathology in 265/300 (88%). The detection rate of the EchoScope for abdominal focal lesion was 172/221 (78%). The higher frequency of the Dual Probe was helpful in 35/300 (12%).
CONCLUSIONS: EchoScopy has proven to display sufficient image quality to answer specific questions, e.g., detection of ascites, splenomegaly, bile duct enlargement, hydronephrosis and other pathological findings which can be judged by "yes/no".

Entities:  

Mesh:

Year:  2019        PMID: 30779825     DOI: 10.11152/mu-1907

Source DB:  PubMed          Journal:  Med Ultrason        ISSN: 1844-4172            Impact factor:   1.611


  2 in total

1.  Miniaturised ultrasound evaluation at the bedside.

Authors:  Katharina Hollerieth; Minh-Truc Vo-Cong; Stephanie Preuss; Stephan Kemmner; Konrad Friedrich Stock
Journal:  World J Urol       Date:  2022-05-18       Impact factor: 4.226

Review 2.  Tele-ultrasound in the Era of COVID-19: A Practical Guide.

Authors:  Christopher Uschnig; Florian Recker; Michael Blaivas; Yi Dong; Christoph F Dietrich
Journal:  Ultrasound Med Biol       Date:  2022-01-10       Impact factor: 3.694

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.