Literature DB >> 30773384

Aortic remodeling after hybrid provisional extension to induce complete attachment aortic repair of chronic residual type I aortic dissection.

Chun-Yang Huang1, Hung-Lung Hsu2, Po-Lin Chen1, Tzu-Ting Kuo1, I-Ming Chen1, Chiao-Po Hsu1, Chun-Che Shih3.   

Abstract

OBJECTIVES: Our objective was to examine the role of the provisional extension to induce complete attachment (PETTICOAT) aortic dissection repair technique with bare metal stents (BMSs) in abdominal remodeling of residual DeBakey type I aortic dissection.
METHODS: We retrospectively reviewed the records of patients with chronic aneurysm formation and residual DeBakey type I aortic dissection (ie, original acute aortic dissection DeBakey type I after primary surgical open repair) who underwent arch reoperation with frozen elephant trunk replacement or endovascular debranching with or without an abdominal BMS between December 2006 and December 2016. We analyzed diameters and volumes in 3 dimensions for the true and false lumens of the thoracic and abdominal aorta as well as the thrombosis percentage of the false lumen between the non-BMS (non-PETTICOAT) and BMS (PETTICOAT) groups.
RESULTS: Forty-seven patients who had completed at least 1 year of follow-up were included. The non-BMS (without abdominal BMS) and BMS groups had significant differences in abdominal true lumen diameter and volumetric change at the first postoperative examination and at the examination 1 year after surgery (26.8 mL, median [19.4-34.1 mL, interquartile range (IQR)]) in non-BMS vs 42.5 mL, median [31.1-57.9 mL, IQR]) in BMS (postoperative survey [F test, 33.775; P = .000]) and (30.1 mL, median [20.5-34.1 mL, IQR] in non-BMS vs 46.6 mL, median [31.3-57.4 mL, IQR]) in BMS (12-month survey [F test, 14.001; P = .001]). The abdominal false lumen thrombosis percentage was higher in the BMS group than in the non-BMS group (25.6%, median [16.4%-58.9%, IQR] in non-BMS vs 54.0%, median [36.7%-65.3%, IQR] in the BMS group (F test, 6.318; P = .016).
CONCLUSIONS: Following reintervention for chronic residual DeBakey type I aortic dissection, PETTICOAT abdominal dissection BMS effectively expanded the thoracic and abdominal true lumen and augmented false lumen thrombosis percentage during the first postoperative year.
Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  PETTICOAT; aortic dissection; aortic remodeling; bare metal stent; residual aortic dissection

Mesh:

Year:  2018        PMID: 30773384     DOI: 10.1016/j.jtcvs.2018.12.041

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Midterm result of custom-made iliac branch device for common iliac aneurysm with and without abdominal aortic aneurysm.

Authors:  Chun-Yang Huang; Po-Lin Chen; Hsin-Ying Lu; Hung-Lung Hsu; Tzu-Ting Kuo; I-Ming Chen; Chiao-Po Hsu; Chun-Che Shih
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-01-01

2.  Aortic remodelling and late outcomes following thoracic endovascular repair with a bare-metal stent distal extension among patients with complicated type-B aortic dissection.

Authors:  Isaac Wamala; Mir Timo Zadegh Nazari-Shafti; Roland Heck; Adam Penkalla; Matteo Montagner; Steven J Staffa; Volkmar Falk; Semih Buz
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-10-10
  2 in total