Literature DB >> 30773254

A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component.

Efthymios Papasoulis1, Theofilos Karachalios2.   

Abstract

PURPOSE: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis.
METHODS: We retrospectively evaluated prospectively collected data from 245 consecutive patients (40 men and 205 women; mean age at surgery 70.1 years, range 44 to 85 years) who underwent 261 TKAs with a mean follow-up of 15.1 years (range 13 to 16 years). Implant failure rate, complication rate, clinical (both subjective and objective) and radiological outcomes were assessed.
RESULTS: At final follow-up, 24 (9.8 %) patients (24 TKAs) were lost to follow-up and 35 (14.3%) patients (35 TKAs) had died for reasons unrelated to surgery. Four TKAs, in four patients, were revised because of aseptic loosening. In five TKAs (five patients) secondary patella resurfacing was performed because of patellofemoral pain. Survivorship analysis showed a cumulative success rate of 98.4% (95% CI, 94.3% - 100%) at 15 years with revision for aseptic loosening as an end point, and 95.6% (95% CI, 92.7% - 98.7%) at 15 years with revision for any reason as an end point. All patients showed a statistically significant improvement (p = 0.01) in the Knee Society clinical rating system, WOMAC Score, KOOS Score, Oxford Knee Score and EuroQol 5D Score. Surgery fulfilled patient expectations for 90.1% of patients; in 5.4% it did not, and 4.5% declined to answer.
CONCLUSION: This study demonstrates satisfactory long-term clinical results for this knee design.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Clinical outcome; Genesis II; Oxidised zirconium; Radiological outcome; Total knee arthroplasty

Mesh:

Substances:

Year:  2019        PMID: 30773254     DOI: 10.1016/j.knee.2019.01.013

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  2 in total

1.  Mid-term clinical outcomes and survivorship of medial-pivot total knee arthroplasty-a mean five year follow-up based on one thousand, one hundred and twenty eight cases.

Authors:  Shuai Xiang; Yingzhen Wang; Chengyu Lv; Changyao Wang; Haining Zhang
Journal:  Int Orthop       Date:  2021-03-30       Impact factor: 3.075

2.  Evaluation of double-high insert mid-term outcomes in cruciate-retaining medial-pivotal total knee arthroplasty - a propensity score-matched analysis with averaged 8-year follow-up.

Authors:  Wenzhe Wang; Shuai Xiang; Yingzhen Wang; Chengyu Lv; Changyao Wang; Haining Zhang
Journal:  BMC Musculoskelet Disord       Date:  2022-06-14       Impact factor: 2.562

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.