Literature DB >> 30773009

Noninvasive Diabetes Monitoring through Continuous Analysis of Sweat Using Flow-Through Glucose Biosensor.

Elena V Karpova1, Elizaveta V Shcherbacheva1, Andrei A Galushin1, Darya V Vokhmyanina1, Elena E Karyakina1, Arkady A Karyakin1.   

Abstract

We propose monitoring of diabetes through continuous analysis of undiluted sweat immediately after its excretion using a flow-through glucose biosensor. The used biosensors are based on Prussian Blue and glucose oxidase immobilized in perfluorosulfonated ionomer or gel of alkoxysilane; the resulting sensitivity with the latter reaches in batch mode 0.23 A M-1 cm-2, and the calibration range is from 1 μM to 1 mM (flow-through mode). On the basis of the glucose tolerance test known to be a clinically relevant procedure to mimic hyperglycemia, a positive correlation between the rates of glucose concentration increase in blood and in noninvasively collected sweat has been observed ( r = 0.75). The observed correlation between sweat and blood considering low-molecular weight metabolites is even better than that observed previously between capillary and vein blood, confirming diagnostic value of sweat for diabetes monitoring. The dynamics of sweat glucose concentration, recorded by means of the proposed biosensor, is in a good accordance with the dynamics of blood glucose content without any time delay, thus offering a prospect for noninvasive monitoring of diabetes.

Entities:  

Year:  2019        PMID: 30773009     DOI: 10.1021/acs.analchem.8b05928

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Antimony-doped tin oxide nanoparticles as peroxidase mimics for paper-based colorimetric detection of glucose using smartphone read-out.

Authors:  Yana Li; Jun Sun; Wei Mao; Sheng Tang; Kai Liu; Tong Qi; Huimin Deng; Wei Shen; Lizhuang Chen; Luming Peng
Journal:  Mikrochim Acta       Date:  2019-06-10       Impact factor: 5.833

2.  Wearable soft electrochemical microfluidic device integrated with iontophoresis for sweat biosensing.

Authors:  Gulcin Bolat; Ernesto De la Paz; Nathalia F Azeredo; Michael Kartolo; Jayoung Kim; Andre Neirdert de Loyola E Silva; Ricardo Rueda; Christopher Brown; Lúcio Angnes; Joseph Wang; Juliane R Sempionatto
Journal:  Anal Bioanal Chem       Date:  2022-01-11       Impact factor: 4.142

3.  State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics.

Authors:  Roozbeh Ghaffari; Da Som Yang; Joohee Kim; Amer Mansour; John A Wright; Jeffrey B Model; Donald E Wright; John A Rogers; Tyler R Ray
Journal:  ACS Sens       Date:  2021-08-05       Impact factor: 9.618

4.  Functional nanostructure-loaded three-dimensional graphene foam as a non-enzymatic electrochemical sensor for reagentless glucose detection.

Authors:  Qianshi Liu; Huage Zhong; Miao Chen; Chang Zhao; Yan Liu; Fengna Xi; Tao Luo
Journal:  RSC Adv       Date:  2020-09-11       Impact factor: 4.036

Review 5.  E-Textiles for Healthy Ageing.

Authors:  Kai Yang; Beckie Isaia; Laura J E Brown; Steve Beeby
Journal:  Sensors (Basel)       Date:  2019-10-15       Impact factor: 3.576

6.  Sampling of fluid through skin with magnetohydrodynamics for noninvasive glucose monitoring.

Authors:  Tuuli A Hakala; Alejandro García Pérez; Melissa Wardale; Ida A Ruuth; Risto T Vänskä; Teemu A Nurminen; Emily Kemp; Zhanna A Boeva; Juha-Matti Alakoskela; Kim Pettersson-Fernholm; Edward Hæggström; Johan Bobacka
Journal:  Sci Rep       Date:  2021-04-07       Impact factor: 4.379

7.  Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators.

Authors:  Masoud Baghelani; Zahra Abbasi; Mojgan Daneshmand; Peter E Light
Journal:  Sci Rep       Date:  2020-07-31       Impact factor: 4.379

Review 8.  Recent Advances in Skin Chemical Sensors.

Authors:  Benoît Piro; Giorgio Mattana; Vincent Noël
Journal:  Sensors (Basel)       Date:  2019-10-10       Impact factor: 3.576

9.  Low-cost portable microwave sensor for non-invasive monitoring of blood glucose level: novel design utilizing a four-cell CSRR hexagonal configuration.

Authors:  Ala Eldin Omer; George Shaker; Safieddin Safavi-Naeini; Hamid Kokabi; Georges Alquié; Frédérique Deshours; Raed M Shubair
Journal:  Sci Rep       Date:  2020-09-16       Impact factor: 4.379

Review 10.  Recent Progress on Semiconductor-Interface Facing Clinical Biosensing.

Authors:  Mingrui Zhang; Mitchell Adkins; Zhe Wang
Journal:  Sensors (Basel)       Date:  2021-05-16       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.