Literature DB >> 30771931

Switchable sniff-cam (gas-imaging system) based on redox reactions of alcohol dehydrogenase for ethanol and acetaldehyde in exhaled breath.

Kenta Iitani1, Yuuki Hayakawa1, Koji Toma2, Takahiro Arakawa2, Kohji Mitsubayashi3.   

Abstract

Measuring the volatile organic compounds (VOCs) released from a human is a promising method for noninvasive disease screening and metabolism assessment. Selectively imaging multiple VOCs derived from human breath and skin gas is expected to improve current gas analysis techniques. In this study, a gas-imaging system (sniff-cam) that can be used to simultaneously image the concentration distribution of multiple VOCs, namely, ethanol (EtOH) and acetaldehyde (AcH), was developed. The sniff-cam was based on the pH-dependent redox reactions of nicotinamide adenine dinucleotide (NAD)-dependent alcohol dehydrogenase (ADH). The sniff-cam was constructed with a camera, two ADH-immobilized meshes, and a UV-LED array sheet. The ADH-immobilized mesh containing a solution of the oxidized form of NAD (NAD+) or reduced form (NADH) was used as an EtOH-imaging mesh and an AcH-imaging mesh, respectively. The distributions of the EtOH and AcH concentrations were visualized through the fluorescence of NADH (the excitation wavelength was 340 nm; the emission wavelength was 490 nm) occurring by the ADH-mediated redox reaction. First, the influence of pH on the activity of the redox reaction of ADH was measured, and then the quantitativeness and selectivity of the sniff-cam were evaluated. The ADH-mediated reactions of EtOH and AcH showed maximum activities at pH 9.0 and pH 6.5, respectively. The sniff-cam demonstrated not only a dynamic range (0.1-1000 ppm for EtOH and 0.2-10 ppm for AcH) for measuring EtOH and AcH in breath after drinking alcohol, but also displayed a high selectivity against other breath VOCs. Finally, EtOH and AcH in breath after drinking alcohol were measured simultaneously. A group with high activity of aldehyde dehydrogenase type 2 (EtOH = 143.3 ± 13.5 ppm, AcH = 1.7 ± 0.2 ppm) and a group with low activity (EtOH = 163.3 ± 28.0 ppm, AcH = 8.4 ± 0.5 ppm) displayed differences in the concentrations of EtOH and AcH contained in their breath samples, and the effectiveness of the developed method was confirmed and compared with previous results. It is suggested that the multiplexed sniff-cam in the future may be capable of selectively and simultaneously imaging various VOCs in human breath and skin gas by using multiple NADH-dependent enzymes.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alcohol dehydrogenase; Fluorescence; Gas imaging; Multiplexed analysis; NADH; Switchable

Mesh:

Substances:

Year:  2018        PMID: 30771931     DOI: 10.1016/j.talanta.2018.12.070

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Adsorption/Combustion-type Micro Gas Sensors: Typical VOC-sensing Properties and Material-design Approach for Highly Sensitive and Selective VOC Detection.

Authors:  Takeo Hyodo; Yasuhiro Shimizu
Journal:  Anal Sci       Date:  2020-02-14       Impact factor: 2.081

2.  How emotional changes affect skin odor and its impact on others.

Authors:  Masako Katsuyama; Tomomi Narita; Masaya Nakashima; Kentaro Kusaba; Masatoshi Ochiai; Naomi Kunizawa; Akihiro Kawaraya; Yukari Kuwahara; Masahiro Horiuchi; Koji Nakamoto
Journal:  PLoS One       Date:  2022-06-30       Impact factor: 3.752

3.  Antarctic aldehyde dehydrogenase from Flavobacterium PL002 as a potent catalyst for acetaldehyde determination in wine.

Authors:  V I Paun; R M Banciu; P Lavin; A Vasilescu; P Fanjul-Bolado; C Purcarea
Journal:  Sci Rep       Date:  2022-10-15       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.