Literature DB >> 30770214

Effect of a synthetic osteoconductive bone graft substitute with zeta potential control (geneX®ds) in the treatment of intertrochanteric fracture: A single center experience of 115 consecutive proximal femoral nail antirotations.

Won Chul Shin1, Jae Hoon Jang2, Jae Yoon Jeong2, Kuen Tak Suh1, Nam Hoon Moon3.   

Abstract

INTRODUCTION: Although various clinical applications of geneX®ds have been reported, no study has reported the clinical application of geneX®ds in osteoporotic hip fracture. The present study aimed to identify the clinical effect of the application of geneX®ds in elderly patients with intertrochanteric fracture treated using proximal femoral nail antirotation (PFNA).
MATERIALS AND METHODS: From March 2014 to October 2017, 233 patients with intertrochanteric fracture (65 men and 168 women) were enrolled in this study. All patients received surgical treatment using PFNA. Patients were classified into two groups: those in whom geneX®ds which is synthetic osteoconductive bone graft substitute with the unique property of Zeta Potential Control (ZPC®), was use, and those in whom it was not. We compared the preoperative details and surgical outcomes, including radiologic outcome (postoperative reduction, tip apex distance, sliding distance of the helical blade, union, and union time) and clinical outcomes (Harris Hip Score and the walking ability at the last follow-up) between the groups.
RESULTS: In patients with unstable fracture who achieved anatomical or extramedullary type of reduction, the average sliding distance at 1, 3, and 12 months was 4.9 mm, 7.5 mmm and 8.1 mm in the geneX®ds group and 7.5 mm, 10.8 mm, and 12.1 mm in the no geneX®ds group, respectively. There were significant differences in the sliding distance at 1, 3, and 12 months between these two groups.
CONCLUSION: The use of this synthetic osteoconductive bone graft substitute with zeta potential control may have positive effect on the controlled sliding of the helical blade and the healing of intertrochanteric fracture.
Copyright © 2019 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30770214     DOI: 10.1016/j.jos.2019.01.010

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  2 in total

1.  Usefulness of Synthetic Osteoconductive Bone Graft Substitute with Zeta Potential Control for Intramedullary Fixation with Proximal Femur Nail Antirotation in Osteoporotic Unstable Femoral Intertrochanteric Fracture.

Authors:  Tae-Woo Sung; Ein-Seong Lee; Ok-Gul Kim; Ki-Seong Heo; Won Yong Shon
Journal:  Hip Pelvis       Date:  2021-12-01

2.  Effects of alendronate sodium combined with InterTan on osteoporotic femoral intertrochanteric fractures and fracture recurrence.

Authors:  Ke-Meng Wang; Shi-Ping Wei; Xiao-Yan Yin; Qing-Ju Meng; Yu-Ming Kong
Journal:  World J Clin Cases       Date:  2022-07-26       Impact factor: 1.534

  2 in total