Using histology to evaluate micro-CT findings of trauma in three post-mortem samples - First steps towards method validation.

Waltraud Baier1, Chas Mangham2, Jason M Warnett3, Mark Payne4, Michelle Painter4, Mark A Williams3.   

Abstract

Forensic imaging technology has rapidly advanced over the past several decades and is gaining increasing significance in medico-legal death investigations. Medical-grade computed tomography (CT) is now routinely used in post-mortem examinations at numerous institutions across the globe. However, the resolution of medical-grade CT is limited and unsuitable when used to depict some smaller anatomical structures or micro-trauma. High-resolution micro-CT offers up to 100× the resolution to overcome this problem but is a very recent addition to the field of forensic radiology. Few studies so far have attempted to validate the results which is an essential prerequisite for it to be used in the criminal justice process as demanded by regulatory bodies. This study directly compares micro-CT images with histology, the current gold standard. Three cases were examined: two larynges from suspected strangulations and one ribcage of a case of fatal child abuse. A strong correlation was observed between histology and micro-CT as the majority of skeletal injuries were identified correctly. This paper discusses the forensic implications of the results and how micro-CT is complementary to histology.
Copyright © 2019 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fracture analysis; Histology; Micro-CT; Validation

Mesh:

Substances:

Year:  2019        PMID: 30769301     DOI: 10.1016/j.forsciint.2019.01.027

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  3 in total

1.  A multi-method assessment of 3D printed micromorphological osteological features.

Authors:  Rachael M Carew; Francesco Iacoviello; Carolyn Rando; Robert M Moss; Robert Speller; James French; Ruth M Morgan
Journal:  Int J Legal Med       Date:  2022-02-09       Impact factor: 2.791

2.  Using micro-computed tomography to examine the larynx in cases of suspected strangulation-a comparison of case findings and control images.

Authors:  Waltraud Baier; Brian A Burnett; Mark Payne; Jason M Warnett; Mark A Williams
Journal:  Int J Legal Med       Date:  2019-11-12       Impact factor: 2.686

3.  Entrapment within an ottoman storage bed: an unusual accidental asphyxial death.

Authors:  Alessandro Cinquetti; Giorgia Franchetti; Giulia Fichera; Chiara Giraudo; Guido Viel; Giovanni Cecchetto
Journal:  Forensic Sci Med Pathol       Date:  2022-03-23       Impact factor: 2.456

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.