Literature DB >> 30763956

Visual Performance, Subjective Satisfaction and Quality of Life Effect of a New Refractive Intraocular Lens with Central Extended Depth of Focus.

Kevin Gillmann1, André Mermoud1.   

Abstract

PURPOSE: To assess the visual performance, clinical and quality of life outcomes, and subjective patient satisfaction after implantation of a new refractive/extended depth of focus (EDOF) hybrid intraocular lens (IOL).
METHODS: This is a monocentric, retrospective study of 29 patients (45 eyes), carried out in a tertiary care glaucoma research centre. All patients underwent implantation of a Lucidis (Swiss Advanced Vision, SAV-IOL SA, Neuchâtel, Switzerland) IOL during cataract surgery. Near, intermediate, and distance best-corrected visual acuities and uncorrected visual acuities were collected at baseline and 3 months postoperatively. Adverse events, contrast sensitivity, optical aberrations, subjective satisfaction, and spectacle independence were also analysed at 3 months.
RESULTS: At 3 months postoperatively, the mean photopic uncorrected monocular distance, and intermediate and near visual acuities were 0.2 logMAR (~ 20/32), 0.07 logMAR (~ 20/23), and 0.15 logMAR (~ 20/28), respectively. Mean best-corrected visual acuity was 0.05 logMAR (~ 20/23) for distance and 0.03 logMAR (~ 20/21) for near vision. Mean photopic contrast sensitivity was 1.5 log. The mean root mean square (RMS) was 0.119 ± 0.05 µm. Subjectively, over the 3-month follow-up, 9% of patients (n = 4) complained of halos, and 2% (n = 1) of photophobia. No other adverse events were noted.
CONCLUSIONS: The Lucidis IOL demonstrates a good safety profile, with an acceptably low complication rate. While the uncorrected visual performance of this new optical design is inferior to that of other EDOF IOLs for distance vision, it achieves better results in intermediate and near vision, with consistently near-normal contrast sensitivity. Interestingly, self-reported spectacle independence and subjective patient satisfaction were high for all distances. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2019        PMID: 30763956     DOI: 10.1055/a-0799-9700

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  2 in total

1.  Visual Outcomes after Implantation of Lucidis EDOF IOL.

Authors:  Mark Rabinovich; Gaia Ceresara; Ana Aramburu Del Boz; Danial Al Khatib; Marie Crespe; Jerome Bovet
Journal:  J Ophthalmol       Date:  2022-05-28       Impact factor: 1.974

Review 2.  Extended Depth-of-Field Intraocular Lenses: An Update.

Authors:  Piotr Kanclerz; Francesca Toto; Andrzej Grzybowski; Jorge L Alio
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.