Literature DB >> 30756433

Non-invasive structure-function assessment of the liver by 2D time-harmonic elastography and the dynamic Liver MAximum capacity (LiMAx) test.

Niklas Heucke1, Tilo Wuensch1, Julia Mohr1, Magnus Kaffarnik1, Ruza Arsenic2, Bruno Sinn2, Tobias Müller3, Johann Pratschke1, Martin Stockmann1, Ingolf Sack4, Heiko Tzschätzsch4.   

Abstract

BACKGROUND AND AIM: Accurate assessment of structural and functional characteristics of the liver could improve the diagnosis and the clinical management of patients with chronic liver diseases. However, the structure-function relationship in the progression of chronic liver disease remains elusive. The aim of this study is the combined measurement of liver function by the 13 C-methacetin Liver MAximum capacity (LiMAx) test and tissue-structure related stiffness by 2D time-harmonic elastography for the assessment of liver disease progression.
METHODS: LiMAx test and time-harmonic elastography were applied, and the serological scores fibrosis 4 index and aspartate aminotransferase to platelet ratio index were calculated in patients with chronic liver diseases (n = 75) and healthy control subjects (n = 22). In 47 patients who underwent surgery, fibrosis was graded by histological examination of the resected liver tissue.
RESULTS: LiMAx values correlated negatively with liver stiffness (r = -0.747), aminotransferase to platelet ratio index (r = -0.604), and fibrosis 4 (r = -0.573). Median (interquartile range) LiMAx values decreased with fibrosis progression from 395 μg/kg/h (371-460 μg/kg/h) in participants with no fibrosis to 173 μg/kg/h (126-309 μg/kg/h) in patients with severe fibrosis. Median liver stiffness increased progressively with the stage of fibrosis from no fibrosis (1.56 m/s [1.52-1.63 m/s]) to moderate fibrosis (1.60 m/s [1.54-1.67 m/s]) to severe fibrosis (1.85 m/s [1.76-1.92 m/s]).
CONCLUSION: Our findings show that structural changes in the liver due to progressing liver diseases and reflected by increased tissue stiffness correlate with a functional decline of the organ as reflected by a decreased metabolic capacity of the liver.
© 2019 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  LiMAx; dynamic liver function test; liver fibrosis; liver stiffness; time-harmonic elastography; ultrasound elastography

Mesh:

Substances:

Year:  2019        PMID: 30756433     DOI: 10.1111/jgh.14629

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  5 in total

Review 1.  [Resection and transplantation for hepatocellular carcinoma and intrahepatic cholangiocarcinoma].

Authors:  Daniel Seehofer; Robert Sucher; Timm Denecke
Journal:  Radiologe       Date:  2022-01-26       Impact factor: 0.635

2.  Valsalva Maneuver Decreases Liver and Spleen Stiffness Measured by Time-Harmonic Ultrasound Elastography.

Authors:  Tom Meyer; Heiko Tzschätzsch; Brunhilde Wellge; Ingolf Sack; Thomas Kröncke; Alma Martl
Journal:  Front Bioeng Biotechnol       Date:  2022-05-26

3.  Tomoelastography based on multifrequency MR elastography predicts liver function reserve in patients with hepatocellular carcinoma: a prospective study.

Authors:  Huimin Lin; Yihuan Wang; Jiahao Zhou; Yuchen Yang; Xinxin Xu; Di Ma; Yongjun Chen; Chunxue Yang; Ingolf Sack; Jing Guo; Ruokun Li; Fuhua Yan
Journal:  Insights Imaging       Date:  2022-06-03

4.  Comparison of preoperative two-dimensional shear wave elastography, indocyanine green clearance test and biomarkers for post hepatectomy liver failure prediction in patients with hepatocellular carcinoma.

Authors:  Rong Fu; Tingting Qiu; Wenwu Ling; Qiang Lu; Yan Luo
Journal:  BMC Gastroenterol       Date:  2021-03-31       Impact factor: 3.067

5.  Changes in Liver Mechanical Properties and Water Diffusivity During Normal Pregnancy Are Driven by Cellular Hypertrophy.

Authors:  Karolina Garczyńska; Heiko Tzschätzsch; Anja A Kühl; Anna Sophie Morr; Ledia Lilaj; Akvile Häckel; Eyk Schellenberger; Nikolaus Berndt; Hermann-Georg Holzhütter; Jürgen Braun; Ingolf Sack; Jing Guo
Journal:  Front Physiol       Date:  2020-11-23       Impact factor: 4.566

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.