| Literature DB >> 30755701 |
Niloufar Torkamani1,2, George Jerums3, Paul Crammer4, Alison Skene5, David A Power5,6, Sianna Panagiotopoulos3, Michele Clarke3, Richard J MacIsaac7, Elif I Ekinci5,3.
Abstract
Mesangial metrics reflect glomerular filtration surface area in diabetes. The point-sampled intercept (PSI) method is the conventional method to calculate these parameters. However, this is time consuming and subject to underestimation. We introduce a novel three-dimensional (3D) reconstruction method applicable to light microscopy to measure mesangial metrics. Transmission electron microscopy (TEM), PSI and our new 3D imaging methods were used to quantify mesangial metrics from 22 patients with type 2 diabetes, normo-, micro- and macroalbuminuria and an estimated glomerular filtration rate of <60 mL/min/1.73 m2. Repeated-measures ANOVA test was used to test the equality of the measurement means from the three methods and the degree of inter method variability. Repeated-measures and post-estimation ANOVA tests together with correlation coefficient measurements were used to compare the methods with TEM as reference. There was a statistically significant difference in mesangial volume measurements (F(2, 16) = 15.53, p = 0.0002). The PSI method underestimated measurements compared to TEM and 3D methods by 30% (p = 0.001) and 15%, respectively (p < 0.001). 3D and TEM measurements did not differ significantly. 3D reconstruction is a reliable and time efficient method for calculating mesangial metrics. It may prove to be a useful tool in clinical and experimental diabetic kidney disease.Entities:
Year: 2019 PMID: 30755701 PMCID: PMC6372585 DOI: 10.1038/s41598-019-38646-z
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Baseline Characteristics.
| Characteristic (n = 22) | Normoalbuminuria (n = 8) | Microalbuminuria (n = 6) | Macroalbuminuria (n = 8) | P value |
|---|---|---|---|---|
| Gender | 3 M, 5 F | 5 M, 1 F | 8 M | 0.04 |
| Age (years) | 67 ± 2* | 69 ± 2.8 | 64 ± 6.8 | 0.16 |
| Duration (years) | 12 ± 2.4 | 12 ± 3.5 | 18.5 ± 8 | 0.17 |
| BMI (kg/m2) | 34 ± 1.6 | 33 ± 2.7 | 29.5 ± 4.6 | 0.51 |
| AER (µg/min) | 7.9 ± 1.2 | 113 ± 19 | 2,276 ± 1,818 | |
| eGFR (ml/min/1.73 m2) | 41 ± 3 | 48 ± 4 | 37 ± 11 | 0.003 |
| Retinopathy | 4/8 | 3/6 | 8/8 | 0.21 |
| Smoker | 0/8 | 3/6 | 2/8 | 0.03 |
| HbA1c (%) | 6.8 ± 0.2 | 8 ± 0.5 | 8.4 ± 1.4 | 0.31 |
| Total Cholesterol (mmol/L) | 4.4 ± 0.2 | 4.1 ± 0.4 | 4.5 ± 1.4 | 0.5 |
*Data shown as mean ± SD. P values were determined by Fisher’s exact test for categorical variables and Kruskal-Wallis for continuous variables. F, female; M, male.
Figure 1Three-dimensional reconstruction of the glomerulus. (a) Glomerular Mesangium (blue) was identified using Reconstruct software based on PAS staining differentiation (scale bar = 50 μm). The eye symbol represents the direction of the view (b) Superior view of glomerulus. 3-dimensional model of the glomerulus was generated using serial horizontal (transverse) sections (c) Close-up view of the 3D model of the glomerular mesangial area. Glomerular mesangial (red) surface area and volume was quantified.
Figure 2Mesangial area quantification using Transmission Electron Microscopy (TEM) and Point Sample Intercept (PSI) methods. (a) Mesangial area and estimated volume was calculated from TEM images (Scale bar 4 µm). Images were analysed (Digimizer 4.2.2) and mesangial area (red) was identified by an expert operator. Transverse sections through the middle of representative glomeruli were chosen and all identifiable mesangial area per glomerulus was measured. The mean mesangial area in a glomerulus per subject was then calculated. (b) Fractional volumes of glomerular components were calculated using PSI method. Using the Cavalieri’s method of segmentation combined with automated point counting (yellow) the mesangial volume was estimated (Fiji by Image J 1.51e) (Scale bar 50 µm).