Literature DB >> 30755120

A minimum 20-year outcome of 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon.

Giuseppe Solarino1, Andrea Piazzolla1, Lorenzo Moretti1, Giovanni Vicenti1, Biagio Moretti1.   

Abstract

BACKGROUND: : Ceramic-on-ceramic (CoC) is currently a viable bearing combination in primary total hip arthroplasty (THA) and, due to its mechanical properties, it can be used in young patients requiring a long-lasting implant. The aim of this study is to report the results of a series of CoC THAs at a minimum 20 years follow-up.
METHODS: : A retrospective study was conducted on the 1st 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon on 51 females and 40 males with an average age of 60.7 years. The mean preoperative Harris Hip Score was 35. The press-fit cup consisted of a pure titanium core with a titanium alloy mesh. Both the inlay and the head were made of dense polycrystalline surgical-grade alumina. The 32-mm femoral head was anchored on 3 different femoral components.
RESULTS: : 19 patients with 22 THAs were died or lost, 2 anatomic cementless stems were revised due to sinking, 1 THA was revised for periprosthetic infection. 2 patients sustained a Vancouver B1 periprosthetic femoral fracture. None of the 78 THAs eligible for this study were revised for wear, breakage, noise of the ceramic components. None of the cups, none of the cemented stems, none of the cementless straight stems failed. HHS raised up to a mean value of 95.
CONCLUSIONS: : The present report demonstrates that CoC coupling offers minimal wear at a long-term follow-up. Further studies are needed to evaluate whether the modern ceramic composites will confirm such excellent results in total hip replacement.

Entities:  

Keywords:  Alumina; ceramic-on-ceramic; hip replacement

Mesh:

Substances:

Year:  2018        PMID: 30755120     DOI: 10.1177/1120700018813218

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  3 in total

1.  What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017.

Authors:  Geir Hallan; Anne Marie Fenstad; Ove Furnes
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

2.  Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems.

Authors:  Giandomenico Logroscino; Michela Saracco; Giulio Maccauro; Andrea Urbani; Domenico Ciavardelli; Ada Consalvo; Daniele Ferraro; Francesco Falez
Journal:  BMC Musculoskelet Disord       Date:  2022-02-22       Impact factor: 2.362

3.  The race for the classification of proximal periprosthetic femoral fractures : Vancouver vs Unified Classification System (UCS) - a systematic review.

Authors:  Clemens Schopper; Matthias Luger; Günter Hipmair; Bernhard Schauer; Tobias Gotterbarm; Antonio Klasan
Journal:  BMC Musculoskelet Disord       Date:  2022-03-23       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.