Literature DB >> 30755093

Development, validation of QuEChERS-based method for simultaneous determination of multiclass pesticide residue in milk, and evaluation of the matrix effect.

Vandana Tripathy1, Krishan Kumar Sharma1, Rajbir Yadav1, Suneeta Devi1, Amol Tayade1, Khushbu Sharma1, Priya Pandey1, Gitansh Singh1, Amar Nath Patel1, Rahul Gautam1, Ruchi Gupta1, Shobhita Kalra1, Poonam Shukla1, Suresh Walia1, Najam Akhtar Shakil2.   

Abstract

Extraction and quantification of pesticide residue from the milk matrix at or below the established maximum residue limit (MRL) is a challenging task for both analytical chemists and the regulatory institutions to take corrective actions for the human health and safety. The main aim of the study is to develop a simple rapid and less expensive QuEChERS extraction and cleanup method for simultaneous analysis of 41 multiclass pesticide residue in milk by gas chromatography-electron capture detector (GC-ECD), followed by confirmation of the residues with gas chromatography-mass spectrometer (GC-MS). Effect of sorbent type, temperature, spiking concentration, matrix effect (ME), measurement uncertainty (MU), inter- and intra-assay repeatability, reproducibility of recovery, and trueness of the results were investigated to validate the effectiveness of the method. Limit of determination (LOD) and limit of quantitation (LOQ) for all the analytes ranged within 0.001-0.02 and 0.002-0.05 µg mL-1, respectively. The % recovery of all the pesticides ranged between 91.38 and 117.56% with relative standard deviation (RSD) below 2.79%. The MU for all the analytes was ≤29% of respective LOQs, and except for few pesticides, the ME was largely negative. The method fulfilled all the SANTE guidelines and thus can be extended for routine analysis of multiclass pesticide residue in milk.

Entities:  

Keywords:  GC-ECD; Multiclass pesticide residues; QuEChERS; dispersive solid-phase extraction; milk

Mesh:

Substances:

Year:  2019        PMID: 30755093     DOI: 10.1080/03601234.2019.1574169

Source DB:  PubMed          Journal:  J Environ Sci Health B        ISSN: 0360-1234            Impact factor:   1.990


  1 in total

1.  Polyaniline functionalized CoAl-layered double hydroxide nanosheets as a platform for the electrochemical detection of carbaryl and isoprocarb.

Authors:  Wei Jiao; Guiyan Ding; Lu Wang; Ying Liu; Tianrong Zhan
Journal:  Mikrochim Acta       Date:  2022-01-29       Impact factor: 5.833

  1 in total