Literature DB >> 30753682

The Experience With Flow Diverters in the Treatment of Posterior Inferior Cerebellar Artery Aneurysms.

Elias Atallah1, Hassan Saad2, Jonathan Li1, Ayan Kumar1, Stavropoula Tjoumakaris1, Nohra Chalouhi1, David Hasan3, Hekmat Zarzour1, Nabeel Herial1, Michael Reid Gooch1, Robert H Rosenwasser1, Pascal Jabbour1.   

Abstract

BACKGROUND: The use of the pipeline embolization device (PED; Medtronic, Dublin, Ireland) in the posterior circulation has been limited and infrequently reported compared to other off-label utilizations. Posterior inferior cerebellar artery aneurysms (PICAA) constitute 1 of the least reported posterior circulation aneurysms treated with PED. No clinical studies have addressed the treatment of these aneurysms with flow diversion exclusively.
OBJECTIVE: To appraise the feasibility and the safety of PED in the treatment of PICAAs.
METHODS: Data on 12 consecutive patients, treated between 2011-2017 with PED for their PICAA, was retrospectively reviewed. To control confounding, we used multivariable logistic regression and propensity score conditioning.
RESULTS: Of 534 patients, 12 (9/12, 75% males) were identified and constituted our study population. The average aneurysm size was 8.47 mm (SD = 2.6, 3.7-14). Patients were followed-up for an average of 10.3 months (SD = 11 mo). Two of 12 (16.7%) had a prior history of subarachnoid hemorrhage. Eight of 12 (67%) of the aneurysms were saccular, 3/12 (25%) were dolichoectatic, and 1/12 (8%) was a small blister aneurysm. Eleven of 12 (92%) aneurysms were treated with 1 PED; 2/12 (16.7%) patients received combined pipeline assisted coiling. All patients had a complete occlusion, regression, and resolution of their aneurysm(s). PED deployment was neither complicated with any hemorrhagic or clinically significant thromboembolic events nor with device migration in any of our patients. Three of 12 (25%) patients had a benign intrastent stenosis. No mortality, among our 12 patients, was noted throughout the follow-up period.
CONCLUSION: PED, deployed by specialized experts, should be safe in treating PICAA. It can be contemplated as a novel alternative treatment of aneurysms located at the PICA-VA bifurcation or within the PICA.
Copyright © 2019 by the Congress of Neurological Surgeons.

Entities:  

Keywords:  Aneurysm; Embolization; PICA; Pipeline; Safety

Year:  2019        PMID: 30753682     DOI: 10.1093/ons/opy301

Source DB:  PubMed          Journal:  Oper Neurosurg (Hagerstown)        ISSN: 2332-4252            Impact factor:   2.703


  4 in total

1.  Flow diverters for the posterior inferior cerebellar artery aneurysms: A systematic review and a single-arm meta-analysis.

Authors:  Xiang Liu; Kunyang Bao; Wenzhang Luo; Weifeng Wan; Tangming Peng; Changren Huang
Journal:  Interv Neuroradiol       Date:  2021-09-14       Impact factor: 1.764

2.  Pipeline embolization of distal posterior inferior cerebellar artery aneurysms.

Authors:  David C Lauzier; Brandon K Root; Yasha Kayan; Josser E Delgado Almandoz; Joshua W Osbun; Arindam R Chatterjee; Kayla L Whaley; Megan E Tipps; Christopher J Moran; Akash P Kansagra
Journal:  Interv Neuroradiol       Date:  2021-04-23       Impact factor: 1.610

3.  Microsurgical Clipping of a Posterior Inferior Cerebellar Artery Aneurysm Following Failed Pipeline Stent.

Authors:  Rishi Suresh; Amanda V Jenson; Gavin Britz
Journal:  Cureus       Date:  2021-02-26

Review 4.  Clinical Importance of the Posterior Inferior Cerebellar Artery: A Review of the Literature.

Authors:  Hui-Lei Miao; Deng-Yan Zhang; Tao Wang; Xiao-Tian Jiao; Li-Qun Jiao
Journal:  Int J Med Sci       Date:  2020-10-18       Impact factor: 3.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.