Literature DB >> 30743308

Simultaneous quantification of levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin in microvolumes of human plasma using high-performance liquid chromatography with ultraviolet detection.

Yi Zheng1,2,3, Ziqing Wang2, Gabrielle Lui1,2,3, Déborah Hirt1,2,3, Jean-Marc Treluyer1,2,3, Sihem Benaboud1,2,3, Radia Aboura1,3, Inès Gana1,3.   

Abstract

Levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin are four fluoroquinolones used in the treatment of serious bacterial infections. The antibacterial activity of fluoroquinolones is concentration dependent. Therefore, therapeutic drug monitoring in daily clinical practice is warranted to ensure the therapy's efficacy and prevent bacterial resistance. The purpose of the present study was to develop a method using high-pressure liquid chromatography with an ultraviolet detector for simultaneous quantification of these four fluoroquinolones in human plasma. A 50 μL aliquot of plasma was precipitated by 200 μL of methanol using gatifloxacin as internal standard. The chromatographic separation was performed on a Kinetex XB-C18 column using a mobile phase composed of a mixture of orthophosphoric acid 0.4% (v/v), acetonitrile and methanol at a flow rate of 1.2 mL/min. Dual UV wavelength mode was used, with levofloxacin and moxifloxacin monitored at 293 nm, and pefloxacin and ciprofloxacin monitored at 280 nm. The calibration was linear over the ranges of 0.125-25 mg/L for levofloxacin, 0.1-20mg/L for moxifloxacin and 0.05-10 mg/L for both pefloxacin and ciprofloxacin. Inter- and intra-day trueness and precision were <13% for all the compounds under study. The proposed method was simple, reliable, cost-effective and suitable for therapeutic drug monitoring or pharmacokinetics studies.
© 2019 John Wiley & Sons, Ltd.

Entities:  

Keywords:  HPLC-UV; TDMpefloxacin; ciprofloxacin; levofloxacin; moxifloxacin

Mesh:

Substances:

Year:  2019        PMID: 30743308     DOI: 10.1002/bmc.4506

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  2 in total

Review 1.  Review of Chromatographic Methods Coupled with Modern Detection Techniques Applied in the Therapeutic Drugs Monitoring (TDM).

Authors:  Tomasz Tuzimski; Anna Petruczynik
Journal:  Molecules       Date:  2020-09-03       Impact factor: 4.411

2.  Population pharmacokinetics of intravenous and oral ciprofloxacin in children to optimize dosing regimens.

Authors:  D Hirt; M Oualha; B Pasquiers; S Blanot; R Rubinstazjn; C Glorion; S El Messaoudi; D Drummond; V Lopez; J Toubiana; A Béranger; Sana Boujaafar; Yi Zheng; Carmen Capito; S Winter; P L Léger; R Berthaud; Inès Gana; F Foissac; J M Tréluyer; N Bouazza; S Benaboud
Journal:  Eur J Clin Pharmacol       Date:  2021-06-23       Impact factor: 2.953

  2 in total