Stuart L Mitchell1,2, William T Obremskey3, Jason Luly2, Michael J Bosse4, Katherine P Frey2, Joseph R Hsu4, Ellen J MacKenzie2, Saam Morshed5, Robert V OʼToole6, Daniel O Scharfstein7, Paul Tornetta8. 1. Department of Orthopaedic Surgery, Johns Hopkins University School of Medicine, Baltimore, MD. 2. Department of Health Policy and Management, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD. 3. Department of Orthopaedic Surgery, Vanderbilt University, Nashville, TN. 4. Department of Orthopaedic Surgery, Carolinas Medical Center, Charlotte, NC. 5. Department of Orthopaedic Surgery, University of California San Francisco, San Francisco, CA. 6. Department of Orthopaedic Surgery, University of Maryland School of Medicine, Baltimore, MD. 7. Department of Biostatistics, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD. 8. Department of Orthopaedic Surgery, Boston University, Boston, MA.
Abstract
OBJECTIVES: To evaluate inter-rater reliability of the modified Radiographic Union Score for Tibial (mRUST) fractures among patients with open, diaphyseal tibia fractures with a bone defect treated with intramedullary nails (IMNs), plates, or definitive external fixation (ex-fix). DESIGN: Retrospective cohort study. SETTING: Fifteen-level one civilian trauma centers; 2 military treatment facilities. PATIENTS/PARTICIPANTS: Patients ≥18 years old with open, diaphyseal tibia fractures with a bone defect ≥1 cm surgically treated between 2007 and 2012. INTERVENTION: Three of 6 orthopedic traumatologists reviewed and applied mRUST scoring criteria to radiographs from the last clinical visit within 13 months of injury. MAIN OUTCOME MEASUREMENTS: Inter-rater reliability was assessed using Krippendorff's alpha (KA) statistic; intraclass correlation coefficient (ICC) is presented for comparison with previous publications. RESULTS: Two hundred thirteen patients met inclusion criteria including 115 IMNs, 24 plates, 29 ex-fixes, and 45 cases that no longer had instrumentation at evaluation. All reviewers agreed on the pattern of scoreable cortices for 90.4% of IMNs, 88.9% of those without instrumentation, 44.8% of rings, and 20.8% of plates. Thirty-one (15%) cases, primarily plates and ex-fixes, did not contribute to KA and ICC estimates because <2 raters scored all cortices. The overall KA for the 85% that could be analyzed was 0.64 (ICC 0.71). For IMNs, plates, ex-fixes, and no instrumentation, KA (ICC) was 0.65 (0.75), 0.88 (0.90), 0.47 (0.62), and 0.48 (0.57), respectively. CONCLUSIONS: In tibia fractures with bone defects, the mRUST seems similarly reliable to previous work in patients treated with IMN but is less reliable in those with plates or ex-fixes, or after removal of instrumentation.
OBJECTIVES: To evaluate inter-rater reliability of the modified Radiographic Union Score for Tibial (mRUST) fractures among patients with open, diaphyseal tibia fractures with a bone defect treated with intramedullary nails (IMNs), plates, or definitive external fixation (ex-fix). DESIGN: Retrospective cohort study. SETTING: Fifteen-level one civilian trauma centers; 2 military treatment facilities. PATIENTS/PARTICIPANTS: Patients ≥18 years old with open, diaphyseal tibia fractures with a bone defect ≥1 cm surgically treated between 2007 and 2012. INTERVENTION: Three of 6 orthopedic traumatologists reviewed and applied mRUST scoring criteria to radiographs from the last clinical visit within 13 months of injury. MAIN OUTCOME MEASUREMENTS: Inter-rater reliability was assessed using Krippendorff's alpha (KA) statistic; intraclass correlation coefficient (ICC) is presented for comparison with previous publications. RESULTS: Two hundred thirteen patients met inclusion criteria including 115 IMNs, 24 plates, 29 ex-fixes, and 45 cases that no longer had instrumentation at evaluation. All reviewers agreed on the pattern of scoreable cortices for 90.4% of IMNs, 88.9% of those without instrumentation, 44.8% of rings, and 20.8% of plates. Thirty-one (15%) cases, primarily plates and ex-fixes, did not contribute to KA and ICC estimates because <2 raters scored all cortices. The overall KA for the 85% that could be analyzed was 0.64 (ICC 0.71). For IMNs, plates, ex-fixes, and no instrumentation, KA (ICC) was 0.65 (0.75), 0.88 (0.90), 0.47 (0.62), and 0.48 (0.57), respectively. CONCLUSIONS: In tibia fractures with bone defects, the mRUST seems similarly reliable to previous work in patients treated with IMN but is less reliable in those with plates or ex-fixes, or after removal of instrumentation.
Authors: Jody Litrenta; Paul Tornetta; William Ricci; Roy W Sanders; Robert V OʼToole; Jason W Nascone; Henry Faber; Darren Wilson Journal: J Orthop Trauma Date: 2017-03 Impact factor: 2.512
Authors: Bauke W Kooistra; Bernadette G Dijkman; Jason W Busse; Sheila Sprague; Emil H Schemitsch; Mohit Bhandari Journal: J Orthop Trauma Date: 2010-03 Impact factor: 2.512
Authors: Jody Litrenta; Paul Tornetta; Samir Mehta; Clifford Jones; Robert V OʼToole; Mohit Bhandari; Stephen Kottmeier; Robert Ostrum; Kenneth Egol; William Ricci; Emil Schemitsch; Daniel Horwitz Journal: J Orthop Trauma Date: 2015-11 Impact factor: 2.512
Authors: Albert H van Houten; Petra J C Heesterbeek; Ronald J van Heerwaarden; Tony G van Tienen; Ate B Wymenga Journal: Clin Orthop Relat Res Date: 2013-11-19 Impact factor: 4.176
Authors: Gillian E Cook; Brent D Bates; Paul Tornetta; Michael D McKee; Saam Morshed; Gerard P Slobogean; Emil H Schemitsch Journal: J Orthop Trauma Date: 2015-12 Impact factor: 2.512
Authors: Christopher C Stewart; Nathan N O'Hara; Sofia Bzovsky; Chelsea S Bahney; Sheila Sprague; Gerard P Slobogean Journal: Bone Joint Res Date: 2022-04 Impact factor: 4.410
Authors: Naomasa Fukase; Victoria R Duke; Monica C Lin; Ingrid K Stake; Matthieu Huard; Johnny Huard; Meir T Marmor; Michel M Maharbiz; Nicole P Ehrhart; Chelsea S Bahney; Safa T Herfat Journal: Sensors (Basel) Date: 2022-08-19 Impact factor: 3.847
Authors: Alexander Coburn; David Shearer; Patrick Albright; Syed Ali; Heather J Roberts; Billy Haonga; Edmund Eliezer; Kevin Chu; Saam Morshed Journal: OTA Int Date: 2020-12-23