Literature DB >> 30740331

"Tailored" endovascular pulmonary valve and root replacement for rupture of a dilated homograft.

Götz Christoph Müller1, Christoph Sinning2, Elvin Zengin-Sahm2, Veronika Stark1, Thomas S Mir1, Carsten Rickers1, Rainer Kozlik-Feldmann1, Tilo Kölbel3, Ulrich Schäfer2.   

Abstract

Current balloon expandable and self-expanding valves have limitations for the treatment of the enlarged right ventricular outflow tract. We report the first use of a tailored Zenith graft in composition with an Edwards Sapien S3 valve as an alternative to high-risk surgery for the treatment of a spontaneously ruptured homograft in an adult congenital heart disease patient.

Entities:  

Keywords:  Pulmonary valve replacement; bleeding; endovascular; enlarged right ventricular outflow tract

Year:  2018        PMID: 30740331      PMCID: PMC6331367          DOI: 10.21037/cdt.2018.11.06

Source DB:  PubMed          Journal:  Cardiovasc Diagn Ther        ISSN: 2223-3652


  5 in total

1.  Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction.

Authors:  P Bonhoeffer; Y Boudjemline; Z Saliba; J Merckx; Y Aggoun; D Bonnet; P Acar; J Le Bidois; D Sidi; J Kachaner
Journal:  Lancet       Date:  2000-10-21       Impact factor: 79.321

2.  Multicenter Experience Evaluating Transcatheter Pulmonary Valve Replacement in Bovine Jugular Vein (Contegra) Right Ventricle to Pulmonary Artery Conduits.

Authors:  Brian H Morray; Doff B McElhinney; Younes Boudjemline; Marc Gewillig; Dennis W Kim; Elena K Grant; Martin L Bocks; Mary H Martin; Aimee K Armstrong; Darren Berman; Saar Danon; Mark Hoyer; Jeffrey W Delaney; Henri Justino; Athar M Qureshi; Jeffery J Meadows; Thomas K Jones
Journal:  Circ Cardiovasc Interv       Date:  2017-06       Impact factor: 6.546

Review 3.  Will catheter interventions replace surgery for valve abnormalities?

Authors:  Michael L O'Byrne; Matthew J Gillespie
Journal:  Curr Opin Cardiol       Date:  2014-01       Impact factor: 2.161

4.  Early versus late functional outcome after successful percutaneous pulmonary valve implantation: are the acute effects of altered right ventricular loading all we can expect?

Authors:  Philipp Lurz; Johannes Nordmeyer; Alessandro Giardini; Sachin Khambadkone; Vivek Muthurangu; Silvia Schievano; Jean-Benoit Thambo; Fiona Walker; Seamus Cullen; Graham Derrick; Andrew M Taylor; Philipp Bonhoeffer
Journal:  J Am Coll Cardiol       Date:  2011-02-08       Impact factor: 24.094

Review 5.  The Melody® valve and Ensemble® delivery system for transcatheter pulmonary valve replacement.

Authors:  Doff B McElhinney; Jill T Hennesen
Journal:  Ann N Y Acad Sci       Date:  2013-07-08       Impact factor: 5.691

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.