Literature DB >> 30739977

Design and Evaluation of an Aerodynamic Focusing Micro-Well Aerosol Collector.

Jiayang He1, Igor V Novosselov1.   

Abstract

Aerosol sampling and identification is vital for the assessment and control of particulate matter pollution, airborne pathogens, allergens, and toxins and their effect on air quality, human health, and climate change. In-situ analysis of chemical and biological airborne components of aerosols on a conventional filter is challenging due to dilute samples in a large collection region. We present the design and evaluation of a micro-well (µ-well) aerosol collector for the assessment of airborne particulate matter (PM) in the 0.5-3 micron size range. The design minimizes particle collection areas allowing for in-situ optical analysis and provides an increased limit of detection for liquid-based assays due to the high concentrations of analytes in the elution/analysis volume. The design of the collector is guided by computational fluid dynamics (CFD) modeling; it combines an aerodynamic concentrator inlet that focuses the aspirated aerosol into a narrow beam and a µ-well collector that limits the particle collection area to the µ-well volume. The optimization of the collector geometry and the operational conditions result in high concentrations of collected PM in the submillimeter region inside the µ-well. Collection efficiency experiments are performed in the aerosol chamber using fluorescent polystyrene microspheres to determine the performance of the collector as a function of particle size and sampling flow rate. The collector has the maximum collection efficiency of about 75% for 1 micron particles for the flow rate of 1 slpm. Particles bigger than 1 micron have lower collection efficiencies because of particle bounce and particle loss in the aerodynamic focusing inlet. Collected samples can be eluted from the device using standard pipettes, with an elution volume of 10-20 microliters. The transparent collection substrate and the distinct collection region, independent of particle size, allows for in-situ optical analysis of the collected PM.

Entities:  

Year:  2017        PMID: 30739977      PMCID: PMC6368264          DOI: 10.1080/02786826.2017.1329515

Source DB:  PubMed          Journal:  Aerosol Sci Technol        ISSN: 0278-6826            Impact factor:   2.908


  2 in total

1.  Online MALDI-TOF MS using an aerodynamic lens assembly as a direct deposition interface.

Authors:  Jinian Shu; Junwang Meng; Xi Shu; Yang Zhang; Shaokai Gao; Bo Yang; Jie Gan
Journal:  Anal Chem       Date:  2010-07-01       Impact factor: 6.986

2.  Reducing bounce effects in the Andersen cascade impactor.

Authors:  Craig Dunbar; Abdo Kataya; Tiba Tiangbe
Journal:  Int J Pharm       Date:  2005-09-14       Impact factor: 5.875

  2 in total
  4 in total

1.  CFD-DEM Coupling Model for Deposition Process Analysis of Ultrafine Particles in a Micro Impinging Flow Field.

Authors:  Yanru Wang; Zhaoqin Yin; Fubing Bao; Jiaxin Shen
Journal:  Micromachines (Basel)       Date:  2022-07-15       Impact factor: 3.523

2.  Miniaturizing Wet Scrubbers for Aerosolized Droplet Capture.

Authors:  Ulri N Lee; Tammi L van Neel; Fang Yun Lim; Jian Wei Khor; Jiayang He; Ravi S Vaddi; Angelo Q W Ong; Anthony Tang; Jean Berthier; John S Meschke; Igor V Novosselov; Ashleigh B Theberge; Erwin Berthier
Journal:  Anal Chem       Date:  2021-08-11       Impact factor: 8.008

3.  Usability of a Personal Air Pollution Monitor: Design-Feedback Iterative Cycle Study.

Authors:  Glen E Duncan; Edmund Seto; Ally R Avery; Mike Oie; Graeme Carvlin; Elena Austin; Jeffry H Shirai; Jiayang He; Byron Ockerman; Igor Novosselov
Journal:  JMIR Mhealth Uhealth       Date:  2018-12-21       Impact factor: 4.773

4.  Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements.

Authors:  Ching-Hsuan Huang; Jiayang He; Elena Austin; Edmund Seto; Igor Novosselov
Journal:  PLoS One       Date:  2021-11-11       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.