Literature DB >> 30739846

Fe(II)-dosed ceramic membrane bioreactor for wastewater treatment: Nutrient removal, microbial community and membrane fouling analysis.

Baoyu Ren1, Chengyue Li1, Xihui Zhang2, Zhenghua Zhang3.   

Abstract

Ferrous dosing is used to reduce phosphorus concentration and alleviate polymeric membrane fouling in membrane bioreactor (MBR). However, limited studies have been conducted to investigate the impacts of ferrous dosing on ceramic membrane fouling, nutrient removal efficiency and microbial community. Accordingly, the aim of this study was to investigate the effect of intermittent ferrous dosing with Fe/P molar ratios of 2 and 1 (with a dosing frequency of every two days) on the overall nutrient removal, functional microbial changes and membrane fouling in ceramic membrane bioreactors (CMBR) in treatment of wastewater. TP concentration of 10 mg/L in influent decreased to 1.94 ± 0.62 mg/L (control), 0.38 ± 0.22 mg/L (Fe/P = 1) and 0.31 ± 0.18 mg/L (Fe/P = 2) in the effluent, respectively. Meanwhile, the effluent total nitrogen (TN) concentrations with Fe/P = 1 treatment (6.80 ± 2.02 mg/L) and Fe/P = 2 treatment (5.12 ± 2.28 mg/L) were lower than that of the control (7.72 ± 2.36 mg/L). Compared to Fe/P = 1, the TN removal performance was better for Fe/P = 2 mainly due to the increased abundance of denitrifying bacteria (Zoogloea and Acinetobacter). In addition, excess iron dose might have toxic effects on bacterial physiology, however the Fe concentrations that cause cell damage vary for different bacteria. The relative abundance of Zoogloea (aerobic denitrifying bacteria) continuously increased with ferrous addition (Fe/P = 2), while other bacteria including Dechloromonas, Hyphomicrobium and Thauera (anoxic denitrifying bacteria), Nitrospira (nitrifying bacteria) and Candidatus Accumulibacter (phosphorus accumulating organism) decreased sharply. Furthermore, membrane fouling was effectively moderated by ferrous dosing and Fe/P = 1 treatment showed improved membrane fouling mitigation than Fe/P = 2. Overall, intermittent ferrous addition in CMBR with Fe/P molar ratio of 1 was beneficial to the removal of nutrients (TP, TN and organics), enhanced succession of microbial community and membrane fouling mitigation.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ceramic membrane; Ferrous; Membrane bioreactor; Membrane fouling; Phosphorus removal

Mesh:

Substances:

Year:  2019        PMID: 30739846     DOI: 10.1016/j.scitotenv.2019.02.019

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  2 in total

1.  In-Situ Sludge Reduction in Membrane-Controlled Anoxic-Oxic-Anoxic Bioreactor: Performance and Mechanism.

Authors:  Chengyue Li; Tahir Maqbool; Hongyu Kang; Zhenghua Zhang
Journal:  Membranes (Basel)       Date:  2022-06-27

2.  In-Situ Sludge Reduction Performance and Mechanism in Sulfidogenic Anoxic-Oxic-Anoxic Membrane Bioreactors.

Authors:  Chengyue Li; Tahir Maqbool; Hongyu Kang; Zhenghua Zhang
Journal:  Membranes (Basel)       Date:  2022-09-08
  2 in total