Carlos M Barrera1, Hayley Ennis1, Gaëtan J-R Delcroix2, David Kaimrajh3, Edward Milne3, Loren Latta3, Michael G Baraga4. 1. University of Miami Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, Florida, U.S.A. 2. Geriatric Research, Education, and Clinical Center and Research Center, Bruce W. Carter Department of Veterans Affairs Medical Center, Miami, Florida, U.S.A.; Nova Southeastern University, Fort Lauderdale, Florida, U.S.A. 3. Department of Orthopaedics, University of Miami, Miami, Florida, U.S.A.; Max Biedermann Institute for Biomechanics, Mount Sinai Medical Center, Miami Beach, Florida, U.S.A. 4. University of Miami Sports Medicine Institute, Miller School of Medicine, University of Miami, Miami, Florida, U.S.A.. Electronic address: mbaraga@med.miami.edu.
Abstract
PURPOSE: To compare the time-zero load to failure of a quadrupled, single-tendon, all-inside anterior cruciate ligament (ACL) reconstruction graft construct with (supplemented) and without the incorporation of inner-limb whipstitch sutures (control) into a tibial suspensory fixation button. METHODS: Eight matched pairs of peroneus longus tendons were prepared according to a quadrupled, all-inside ACL soft-tissue graft technique with 1 side serving as a control and the contralateral side supplemented. The constructs were biomechanically tested for strain in the inner and outer limbs during a preconditioning protocol, single-cycle load to failure, and elongation of the whole construct. RESULTS: Ultimate load to failure was significantly higher in the supplemented group: 797.5 ± 49.6 N (95% confidence interval [CI], 763.13-831.87 N) versus 719.6 ± 69.6 N (95% CI, 671.38-767.82 N; P = .044). Less graft elongation at failure was observed in the supplemented group (3.1 ± 1.5 mm; 95% CI, 2.07-4.17 mm) versus the control group (21.0 ± 21.2 mm; 95% CI, 6.31-35.69 mm; P = .052). The number of grafts undergoing a 5-mm or greater change in length at failure was 1 of 8 in the supplemented group versus 5 of 8 in the control group (P = .038). CONCLUSIONS: Inner-limb supplemental tibial fixation results in higher time-zero load to failure and decreased graft elongation in a quadrupled, single-tendon, all-inside ACL reconstruction graft construct. CLINICAL RELEVANCE: The weak point of a single-tendon, quadrupled, all-inside ACL graft construct is the tendon-to-tendon suturing to secure the inner limbs of the graft. Adding supplemental fixation by incorporating the sutures from the inner limb to the tibial suspensory fixation button leads to a higher time-zero load to failure and decreased graft elongation.
PURPOSE: To compare the time-zero load to failure of a quadrupled, single-tendon, all-inside anterior cruciate ligament (ACL) reconstruction graft construct with (supplemented) and without the incorporation of inner-limb whipstitch sutures (control) into a tibial suspensory fixation button. METHODS: Eight matched pairs of peroneus longus tendons were prepared according to a quadrupled, all-inside ACL soft-tissue graft technique with 1 side serving as a control and the contralateral side supplemented. The constructs were biomechanically tested for strain in the inner and outer limbs during a preconditioning protocol, single-cycle load to failure, and elongation of the whole construct. RESULTS: Ultimate load to failure was significantly higher in the supplemented group: 797.5 ± 49.6 N (95% confidence interval [CI], 763.13-831.87 N) versus 719.6 ± 69.6 N (95% CI, 671.38-767.82 N; P = .044). Less graft elongation at failure was observed in the supplemented group (3.1 ± 1.5 mm; 95% CI, 2.07-4.17 mm) versus the control group (21.0 ± 21.2 mm; 95% CI, 6.31-35.69 mm; P = .052). The number of grafts undergoing a 5-mm or greater change in length at failure was 1 of 8 in the supplemented group versus 5 of 8 in the control group (P = .038). CONCLUSIONS: Inner-limb supplemental tibial fixation results in higher time-zero load to failure and decreased graft elongation in a quadrupled, single-tendon, all-inside ACL reconstruction graft construct. CLINICAL RELEVANCE: The weak point of a single-tendon, quadrupled, all-inside ACL graft construct is the tendon-to-tendon suturing to secure the inner limbs of the graft. Adding supplemental fixation by incorporating the sutures from the inner limb to the tibial suspensory fixation button leads to a higher time-zero load to failure and decreased graft elongation.