Literature DB >> 30736995

Supplemental Fixation of Inner Graft Limbs in All-Inside, Quadrupled, Single-Tendon Anterior Cruciate Ligament Reconstruction Graft Construct Yields Improved Biomechanical Properties.

Carlos M Barrera1, Hayley Ennis1, Gaëtan J-R Delcroix2, David Kaimrajh3, Edward Milne3, Loren Latta3, Michael G Baraga4.   

Abstract

PURPOSE: To compare the time-zero load to failure of a quadrupled, single-tendon, all-inside anterior cruciate ligament (ACL) reconstruction graft construct with (supplemented) and without the incorporation of inner-limb whipstitch sutures (control) into a tibial suspensory fixation button.
METHODS: Eight matched pairs of peroneus longus tendons were prepared according to a quadrupled, all-inside ACL soft-tissue graft technique with 1 side serving as a control and the contralateral side supplemented. The constructs were biomechanically tested for strain in the inner and outer limbs during a preconditioning protocol, single-cycle load to failure, and elongation of the whole construct.
RESULTS: Ultimate load to failure was significantly higher in the supplemented group: 797.5 ± 49.6 N (95% confidence interval [CI], 763.13-831.87 N) versus 719.6 ± 69.6 N (95% CI, 671.38-767.82 N; P = .044). Less graft elongation at failure was observed in the supplemented group (3.1 ± 1.5 mm; 95% CI, 2.07-4.17 mm) versus the control group (21.0 ± 21.2 mm; 95% CI, 6.31-35.69 mm; P = .052). The number of grafts undergoing a 5-mm or greater change in length at failure was 1 of 8 in the supplemented group versus 5 of 8 in the control group (P = .038).
CONCLUSIONS: Inner-limb supplemental tibial fixation results in higher time-zero load to failure and decreased graft elongation in a quadrupled, single-tendon, all-inside ACL reconstruction graft construct. CLINICAL RELEVANCE: The weak point of a single-tendon, quadrupled, all-inside ACL graft construct is the tendon-to-tendon suturing to secure the inner limbs of the graft. Adding supplemental fixation by incorporating the sutures from the inner limb to the tibial suspensory fixation button leads to a higher time-zero load to failure and decreased graft elongation.
Copyright © 2019 Arthroscopy Association of North America. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 30736995     DOI: 10.1016/j.arthro.2018.10.130

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  1 in total

1.  Biomechanical Comparison of Graft Preparation Techniques for All-Inside Anterior Cruciate Ligament Reconstruction.

Authors:  Julia Bowes; Nada Mohamed; Jonelle Jn Baptiste; Lindsey Westover; Catherine Hui; Mark Sommerfeldt
Journal:  Orthop J Sports Med       Date:  2020-07-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.