Deborah Rohner1, Michael P Kowaleski2, Günter Schwarz3, Franck Forterre1. 1. Division of Small Animal Surgery, Department Clinical Veterinary Medicine, Vetsuisse Faculty, Bern, Switzerland. 2. Department of Clinical Sciences, Cummings School of Veterinary Medicine, Tufts University, North Grafton, Massachusetts, United States. 3. Tierklinik Hollabrunn, Hollabrunn, Austria.
Abstract
OBJECTIVES: The purpose of this study was to assess the short-term outcome of a new intervertebral anchored fusion device (C-LOX) for the treatment of disc associated cervical spondylomyelopathy (DA-CSM) in dogs, based on clinical and radiographical follow-up data. MATERIALS AND METHODS: To be included in the study, dogs had to be clinically affected by DA-CSM treated with surgical distraction/stabilization using the anchored intervertebral spacer (C-LOX). Neurological signs, as well as diagnostic imaging performed pre-, immediately postoperatively, and after 6 weeks and 3 months were assessed. If available, clinical follow-up after 3 months was documented. RESULTS: Thirty-seven cases were enrolled in the study. Outcome at 3 months was available in 25 dogs; improvement of neurological status was documented in 25/25 cases.The most common postoperative complication was screw loosening and/or breakage (n = 22), followed by subsidence (n = 15). Four dogs required revision surgery. CLINICAL SIGNIFICANCE: Distraction/stabilization of DA-CSM in dogs with the C-LOX device resulted in short-term clinical improvement in 33/37 treated cases. The high incidence of screw loosening was taken into consideration and modification of the implant with a new locking system and new screw dimensions was required. The C-LOX device seems to be a valuable alternative to more complicated distraction-fusion techniques. Georg Thieme Verlag KG Stuttgart · New York.
OBJECTIVES: The purpose of this study was to assess the short-term outcome of a new intervertebral anchored fusion device (C-LOX) for the treatment of disc associated cervical spondylomyelopathy (DA-CSM) in dogs, based on clinical and radiographical follow-up data. MATERIALS AND METHODS: To be included in the study, dogs had to be clinically affected by DA-CSM treated with surgical distraction/stabilization using the anchored intervertebral spacer (C-LOX). Neurological signs, as well as diagnostic imaging performed pre-, immediately postoperatively, and after 6 weeks and 3 months were assessed. If available, clinical follow-up after 3 months was documented. RESULTS: Thirty-seven cases were enrolled in the study. Outcome at 3 months was available in 25 dogs; improvement of neurological status was documented in 25/25 cases.The most common postoperative complication was screw loosening and/or breakage (n = 22), followed by subsidence (n = 15). Four dogs required revision surgery. CLINICAL SIGNIFICANCE: Distraction/stabilization of DA-CSM in dogs with the C-LOX device resulted in short-term clinical improvement in 33/37 treated cases. The high incidence of screw loosening was taken into consideration and modification of the implant with a new locking system and new screw dimensions was required. The C-LOX device seems to be a valuable alternative to more complicated distraction-fusion techniques. Georg Thieme Verlag KG Stuttgart · New York.
Authors: Tjarda E Reints Bok; Koen Willemsen; Mattie H P van Rijen; Guy C M Grinwis; Marianna A Tryfonidou; Björn P Meij Journal: Vet Surg Date: 2019-08-22 Impact factor: 1.495