Literature DB >> 30732729

Preclinical Evaluation of a Novel Sirolimus-Eluting Iron Bioresorbable Coronary Scaffold in Porcine Coronary Artery at 6 Months.

Jian-Feng Zheng1, Hong Qiu2, Yuan Tian3, Xiao-Ying Hu1, Tong Luo1, Chao Wu1, Yi Tian4, Yue Tang4, Lai-Feng Song5, Li Li5, Liang Xu1, Bo Xu1, Run-Lin Gao6.   

Abstract

OBJECTIVES: The aim of this study was to investigate the operability, 6-month efficacy, and safety of the novel sirolimus-eluting iron bioresorbable coronary scaffold (IBS) system compared with a cobalt-chromium everolimus-eluting stent (EES) (XIENCE Prime stent) in porcine coronary arteries.
BACKGROUND: Bioresorbable scaffolds have been considered the fourth revolution in percutaneous coronary intervention. However, the first-generation bioresorbable scaffold showed suboptimal results.
METHODS: Forty-eight IBS and 48 EES were randomly implanted into nonatherosclerotic swine. The operability, efficacy, and safety of the IBS and EES were evaluated using coronary angiography, optical coherence tomography, micro-computed tomography, scanning electron microscopy, and histopathologic evaluation at 7, 14, 28, 90, and 180 days after implantation.
RESULTS: The operability of the ultrathin IBS (∼70 μm) was comparable with that of the EES, except for its visibility. There was no statistically significant difference in area stenosis between the IBS and EES from 28 to 180 days. The IBS maintained its integrity up to 90 days without corrosion, while corrosion was observed in a few struts in 2 of 10 IBS at 180 days. The percentage of endothelialization of IBS was higher than that of XIENCE Prime stents within 14 days after implantation. The fibrin score was higher in the IBS group at 28 days but comparable with the EES group at 90 and 180 days. No scaffold or stent thrombosis was seen in either group. No abnormal histopathologic changes in scaffolded or stented vessel segments and 5 main remote organs were observed in either group.
CONCLUSIONS: Preclinical results suggest that the novel IBS has comparable operability, mid-term efficacy, and safety with the EES, and its corrosion profile in porcine coronary arteries is reasonable, which could support initial clinical study of the IBS.
Copyright © 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bioresorbable scaffold; preclinical study; sirolimus-eluting iron bioresorbable coronary scaffold

Mesh:

Substances:

Year:  2019        PMID: 30732729     DOI: 10.1016/j.jcin.2018.10.020

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  13 in total

1.  Feasibility, safety, and efficacy of iron bioresorbable scaffold in neonates with duct-dependent pulmonary circulation.

Authors:  Marhisham Che Mood; Khalil Ahmad Niazy; Mazeni Alwi; Hasri Samion; Koh Ghee Tiong; Sivakumar Sivalingam; Deyuan Zhang
Journal:  Ann Pediatr Cardiol       Date:  2022-08-19

2.  Experimental study on novel biodegradable Zn-Fe-Si alloys.

Authors:  Yuxin Zeng; Zeyi Guan; Chase S Linsley; Shuaihang Pan; Jingke Liu; Benjamin M Wu; Xiaochun Li
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2022-05-06       Impact factor: 3.405

3.  Designing Better Cardiovascular Stent Materials - A Learning Curve.

Authors:  Irsalan Cockerill; Carmine Wang See; Marcus L Young; Yadong Wang; Donghui Zhu
Journal:  Adv Funct Mater       Date:  2020-11-04       Impact factor: 18.808

4.  PDLLA-Zn-nitrided Fe bioresorbable scaffold with 53-μm-thick metallic struts and tunable multistage biodegradation function.

Authors:  Danni Shen; Haiping Qi; Wenjiao Lin; Wanqian Zhang; Dong Bian; Xiaoli Shi; Li Qin; Gui Zhang; Wenchao Fu; Kefei Dou; Bo Xu; Zhenyuan Yin; Jiancun Rao; Mazeni Alwi; Shuhan Wang; Yufeng Zheng; Deyuan Zhang; Runlin Gao
Journal:  Sci Adv       Date:  2021-06-04       Impact factor: 14.136

5.  Magnetic resonance (MR) safety and compatibility of a novel iron bioresorbable scaffold.

Authors:  Dong Bian; Li Qin; Wenjiao Lin; Danni Shen; Haiping Qi; Xiaoli Shi; Gui Zhang; Hongwei Liu; Han Yang; Jin Wang; Deyuan Zhang; Yufeng Zheng
Journal:  Bioact Mater       Date:  2020-02-25

6.  Anti-CD34-Grafted Magnetic Nanoparticles Promote Endothelial Progenitor Cell Adhesion on an Iron Stent for Rapid Endothelialization.

Authors:  Jialong Chen; Shuang Wang; ZiChen Wu; Zhangao Wei; Weibo Zhang; Wei Li
Journal:  ACS Omega       Date:  2019-11-07

7.  Construction of a Novel Ferroptosis-Related Gene Signature of Atherosclerosis.

Authors:  Tucheng Huang; Kangjie Wang; Yuewei Li; Yanchen Ye; Yangxin Chen; Jingfeng Wang; Chen Yao
Journal:  Front Cell Dev Biol       Date:  2022-01-05

Review 8.  Current status and outlook of biodegradable metals in neuroscience and their potential applications as cerebral vascular stent materials.

Authors:  Ming Li; Miaowen Jiang; Yuan Gao; Yufeng Zheng; Zhi Liu; Chen Zhou; Tao Huang; Xuenan Gu; Ang Li; Jiancheng Fang; Xunming Ji
Journal:  Bioact Mater       Date:  2021-10-11

9.  Long-term safety and absorption assessment of a novel bioresorbable nitrided iron scaffold in porcine coronary artery.

Authors:  Jian-Feng Zheng; Zi-Wei Xi; Yang Li; Jia-Nan Li; Hong Qiu; Xiao-Ying Hu; Tong Luo; Chao Wu; Xin Wang; Lai-Feng Song; Li Li; Hai-Ping Qi; Gui Zhang; Li Qin; Wan-Qian Zhang; Xiao-Li Shi; Shu-Han Wang; De-Yuan Zhang; Bo Xu; Run-Lin Gao
Journal:  Bioact Mater       Date:  2022-01-11

Review 10.  Bioresorbable Scaffolds: Contemporary Status and Future Directions.

Authors:  Xiang Peng; Wenbo Qu; Ying Jia; Yani Wang; Bo Yu; Jinwei Tian
Journal:  Front Cardiovasc Med       Date:  2020-11-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.