| Literature DB >> 30732579 |
Mami Ogita1,2, Kenji Sekiguchi3,4, Keiko Akahane5, Ryoko Ito3, Chiori Haga3, Satoru Arai6, Yasushi Ishida7, Jiro Kawamori3.
Abstract
BACKGROUND: We conducted a randomized trial to evaluate the efficacy of heparinoid moisturization for radiation dermatitis. We report the time-course of sebum content after whole breast radiotherapy (WBRT) and the efficacy of heparinoid moisturizer.Entities:
Keywords: Breast cancer; Moisturizer; Radiotherapy; Sebaceous gland damage
Mesh:
Substances:
Year: 2019 PMID: 30732579 PMCID: PMC6367742 DOI: 10.1186/s12885-019-5334-9
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Fig. 1The Consort flow diagram. WBRT; whole breast radiotherapy
Patient baseline characteristics
| Prophylaxis ( | Post WBRT ( | Control ( |
| ||||
|---|---|---|---|---|---|---|---|
|
| % |
| % |
| % | ||
| Age (year) | |||||||
| Median (range) | 45 (34–65) | 49 (32–65) | 50 (39–65) | 0.13 | |||
| BMI | |||||||
| Median (range) | 21.3 (17–28) | 22.3 (17–33) | 20.9 (16–29) | 0.28 | |||
| Affected breast | |||||||
| Left | 8 | 57 | 18 | 60 | 14 | 44 | 0.4 |
| Right | 6 | 23 | 12 | 40 | 18 | 56 | |
| Tumor location | |||||||
| Inner | 0 | 0 | 2 | 7 | 1 | 3 | 0.24 |
| Lateral | 13 | 93 | 28 | 93 | 29 | 91 | |
| Central | 1 | 7 | 0 | 0 | 2 | 6 | |
| Smoking | |||||||
| Current | 0 | 0 | 0 | 0 | 1 | 3 | 0.74 |
| Past | 4 | 29 | 6 | 20 | 6 | 19 | |
| Never | 10 | 71 | 24 | 80 | 25 | 78 | |
| Chemotherapy before RT | |||||||
| Yes | 4 | 29 | 5 | 83 | 4 | 13 | 0.41 |
| No | 10 | 71 | 25 | 17 | 28 | 87 | |
| Endocrine therapy before RT | |||||||
| Yes | 1 | 7 | 2 | 7 | 1 | 3 | 0.77 |
| No | 13 | 93 | 28 | 93 | 31 | 97 | |
| RT | |||||||
| Energy (MV) | |||||||
| 4 | 10 | 72 | 18 | 60 | 24 | 75 | 0.43 |
| 6 | 4 | 29 | 12 | 40 | 8 | 25 | |
| Boost | |||||||
| 10–18 Gy | 9 | 64 | 15 | 50 | 16 | 50 | 0.63 |
| No | 5 | 36 | 15 | 50 | 16 | 50 | |
BMI; body mass index, RT; radiotherapy, WBRT; whole breast radiotherapy
Fig. 2Time course of sebum content by sebumeter in the irradiated (a) and non-irradiated breast (b). a * P < 0.05 comparison between baseline and each time point. ** P < 0.05 comparison between control group and each group. RT; radiotherapy; WBRT; whole breast radiotherapy. b * P < 0.05 comparison between baseline and each time point. ** P < 0.05 comparison between control group and each group. RT; radiotherapy; WBRT; whole breast radiotherapy
Sebum content by sebumeter in the irradiated (a) and non-irradiated breast (b)
| Prophylaxis ( | vs Control | Post-WBRT ( | vs Control | Control ( | |
|---|---|---|---|---|---|
| Mean (μg/cm2) (± SD) |
| Mean (μg/cm2) (± SD) |
| Mean (μg/cm2) (± SD) | |
| a. Irradiated breast | |||||
| Pre-RT | 9.6 (± 10.6) | 0.66 | 11.1 (± 14.6) | 0.5 | 12.3 (± 16.5) |
| Last day of WBRT | 16.2 (± 16.1) | < 0.01 | 1.3 (± 4.6) | 0.87 | 0.5 (± 1.2) |
| 2w post-RT | 16.0 (± 13.4) | < 0.01 | 1.5 (± 3.8) | 0.81 | 0.5 (± 0.7) |
| 4w post-RT | 15.2 (± 15.1) | < 0.01 | 10.7 (± 12.4) | < 0.01 | 0.4 (± 0.7) |
| 3 m post-RT | 10.0 (± 12.3) | < 0.01 | 4.9 (± 8.8) | 0.01 | 0.4 (± 0.6) |
| b. Non-irradiated breast | |||||
| Pre-RT | 8.9 (± 12.2) | 0.52 | 10.2 (± 18.2) | 0.34 | 11.9 (± 15.4) |
| Last day of WBRT | 4.2 (± 6.6) | 0.45 | 2.2 (± 4.5) | 0.27 | 2.6 (± 3.9) |
| 2w post RT | 5.8 (± 8.5) | 0.03 | 1.9 (± 4.1) | 1 | 3.0 (± 6.5) |
| 4w post RT | 6.2 (± 7.9) | 0.15 | 7.4 (± 9.5) | 0.08 | 4.1 (± 6.0) |
| 3 m post RT | 6.8 (± 5.9) | 0.23 | 6.7 (± 9.5) | 0.75 | 6.0 (± 8.8) |
RT; radiotherapy, WBRT; whole breast radiotherapy
Fig. 3Sebum composition in the irradiated and non-irradiated breast of 15 patients in the control group. WE; Wax ester, SQ; Squalene, TG; Triglyceride, CH; Cholesterol, FFA; Free fatty acids
The influence of the distance from the irradiated field on sebum content by ELSD
| Irradiated area | Non-irradiated inner | Non-irradiated middle | Non-irradiated outer |
| ||||
|---|---|---|---|---|---|---|---|---|
| Mean (μg/cm2) (± SD) |
| Mean (μg/cm2) (± SD) |
| Mean (μg/cm2) (± SD) |
| Mean (μg/cm2) (± SD) | ||
| Pre-RT ( | 15.0 (± 26.2) | 11.0 (± 18.5) | 6.4 (± 1.0) | 3.5 (± 6.5) | ||||
| 2w post RT (n = 7) | 0.08 (± 0.10) | 0.02 | 2.7 (± 2.7) | 0.02 | 1.6 (± 2.1) | 0.09 | 1.3 (± 2.1) | 0.13 |
| 3 m post RT ( | 0.23 (± 0.33) | 0.03 | 12.5 (± 24.0) | 0.6 | 6.9 (± 13.2) | 0.75 | 2.8 (± 5.0) | 0.46 |
ELSD; evaporative light scattering detector, RT; radiotherapy