Application of 82 Sr/82 Rb generator in neurooncology.

Nikolay A Kostenikov1, Boris L Zhuikov2, Valeriy M Chudakov2, Yuriy R Iliuschenko1, Sergey V Shatik1, Vadim V Zaitsev1, Dmitriy S Sysoev1, Andrey A Stanzhevskiy1.   

Abstract

INTRODUCTION: The applicability of "Rubidium Chloride, 82 Rb from Generator" radiopharmaceutical for brain tumors (BT) diagnostics is demonstrated on the basis of the application experience of the radiopharmaceutical in neurooncology. EXPERIMENTAL: A total of 21 patients with various brain tumors and nonneoplastic abnormal brain masses were investigated. RESULTS AND DISCUSSIONS: The results of the imaging and differential diagnostics of malignant and benign tumors, nonneoplastic abnormal brain masses and lesions revealed the prevalence of high uptake of the radiopharmaceutical in the malignant tumors in comparison with benign glioma and arteriovenous malformations in which 82 Rb-chloride accumulates in the vascular phase but does not linger further. The ultra-short half-life of radionuclide 82 Rb (76 s) along with a low absorbed radiation dose with 82 Rb-chloride by intravenous administration create a new possibility of successive use of two or more radiopharmaceuticals for the examination of the same patient. For instance, PET examination with 18 F-FDG, 11 C-methionine, 11 C-choline, or any other radiopharmaceutical can be carried out in just 7-15 min. after 82 Rb-chloride injection.
CONCLUSION: Research demonstrated an effectiveness of 82 Rb-chloride application as a diagnostic agent in neurooncology. A method of dosing and administration of the generator-produced radiopharmaceutical has been worked out. It is possible to do up to 600 PET sessions using one Russian 82 Rb generator GR-01. The generator is proved to be reliable and easy to use. The interest in 82 Rb-chloride as a tumor-seeking radiopharmaceutical rose due to the active application of the modern devices PET/CT in the routine clinical practice.
© 2019 Institution for Nuclear Research of Russian Academy of Science (INR RAS) Brain and Behavior Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  82Rb-chloride; 82Sr/82Rb generator; PET; brain tumors; radiopharmaceutical

Mesh:

Substances:

Year:  2019        PMID: 30729720      PMCID: PMC6422714          DOI: 10.1002/brb3.1212

Source DB:  PubMed          Journal:  Brain Behav            Impact factor:   2.708


INTRODUCTION

The references of using 82Sr/82Rb generator (82Rb generator) for positron‐emission tomography (PET) dates back to the 70 s (Kulprathipanja, Hnatowich, & Ben, 1979; Yano & Roth, 1979). Generator for clinical use based on hydrated tin oxide were developed in the USA (Neidrickx, 1980), the UK (Waters, Horlock, & Kensett, 1983), Switzerland (Beyer, Rӧsch, & Ravn, 1990), Canada (Cackette, Ruth, & Vincent, 1993), Russia (Kodina, Kurenkov, Kurchatova, Malinin, & Yu, 1991; Litvinov et al., 1997), and Korea (Jeong et al., 1994). At present, the 82Rb‐generators are mainly produced in the USA by GE Healthcare and distributed by Bracco Diagnostics Inc. (CardioGen®) (Bracco Diagnostics2000‐2000, 2000) (approved by FDA in 1989), as well as recently in Canada by Jubilant DraxImage (Ruby‐Fill®) (Jubilant DraxImage, 2018) (approved by FDA in 2016). The Russian 82Rb generator GR‐01 which is produced and used at the clinic of the Russian Research Center of Radiology and Surgical Technologies of Ministry of Public Health (RRCRST, St. Petersburg) was developed in the Institute for Nuclear Research of Russian Academy of Sciences (INR, Moscow) with the participation of TRIUMF (Vancouver, Canada) (Chudakov et al., 2005, 2014; Chudakov, Zhuikov, & Ermolaev, 2015; Chudakov, Zhuikov, & Kokhanuk, 2015). A new approach of 82Rb clinical application for PET 002Ddiagnostics in cardiology and later in oncology was developed in RRCRST in 2005–2007 (Granov, Matveev, Zhuikov, Kostenikov, & Rizhkova, 2011; Granov, Tyutin, & Kostenikov, 2012; Granov, Tyutin, Tlostanova, Rizhkova, & Kostenikov, 1997). Preclinical and clinical trials of the 82Rb generator were carried out in the RRCRST in 2005–2011. The 82Rb generator was registered as a medical device by Federal Service for Surveillance in Healthcare of Russian Federation in 2014 (Registration certificate of medical production No RZN 2014, 2014). The generator‐produced radiopharmaceutical has an important advantage: it does not require a complicated and expensive cyclotron–radiochemical complex. Due to a short half‐life of 82Rb (76 s), the absorbed dose of radiation is low for a patient. It gives the opportunity to repeat testing many times as well as to use several radiopharmaceuticals successively within one day for the same patient. Earlier the generator was used almost in cardiology only (Chatal et al., 2015). The first study of brain tumors perfusion of using PET with 82Rb‐chloride was carried out in 1980–90 s (Brooks et al., 1984; Roelcke et al., 1996; Yen et al., 1982). The attention was paid to 82Rb+ property to penetrate the blood‐brain barrier (BBB). In particular, some authors studied 82Rb‐chloride diagnostic capabilities during the estimation of blood‐brain barrier permeability in patients with glial tumors and metastatic brain lesions (Brooks et al., 1984). The obtained results showed the capacity of 82Rb‐chloride to higher uptake in the areas with a damaged blood‐brain barrier. The diagnostic accuracy of the method was similar to the data of the perfusion X‐ray computed tomography (PCT) and magnetic resonance perfusion imaging (MRI). Advantages and disadvantages of MRI and PET in perfusion study are not yet well investigated. At perfusion investigation with MRI, the extent of analyzed zone of interest is limited by the size of the field of view of the tomograph. This makes difficult to scan necessary volume of human brain in some cases. Susceptibility artifacts, especially in zones of the frontal sinus and ethmoid labyrinth may appear (Jarnum et al., 2010) at MRI investigation. The results of measurement are very sensitive to technical parameters of the scanner. The proposed method of PET investigation with 82Rb‐chloride is free from these disadvantages. An information obtained with 82Rb‐chloride PET investigations is especially effective in combination with contrast‐enhanced MRI using PET/MRI fusion technique. In this case, a final conclusion on the role and advantage of PET with 82Rb‐chloride in brain tumor studies may be drawn (Nensa, Beiderwellen, Heusch, & Wetter, 2014). This approach is simple, reproducible, and provides obtaining exact information on tumor perfusion. Short period of 82Rb half‐life provides low radiation doses. The authors set protocols for the PET data acquisition and mathematical models to calculate a constant, which shows the rate of intracellular transportation of rubidium‐82 cations into the brain tumor cells (Brooks et al., 1984). The interest in 82Rb‐chloride as a tumor‐seeking radiopharmaceutical rose 2010–2011 due to the active application of the new multimodal device PET‐CT in the routine clinical practice (Kale, Halkar, & Galt, 2007; Khandani, Sheikh, Beavers, & Ivanovic, 2010; Mirpour & Khandani, 2011). So far, there are few reports (Brooks et al., 1984; Kale et al., 2007; Khandani et al., 2010; Mirpour & Khandani, 2011; Roelcke et al., 1996; Yen et al., 1982) on the capability and diagnostic efficiency of 82Rb‐chloride in neurooncology. But in these researches, the authors mainly focus on comparing 82Rb‐chloride and 11Cmethionine without paying much attention to the significant aspect mentioned above. The comparison of 82Rb‐chloride diagnostic capability with those of 18F‐FDG is considered highly important, since the two radiopharmaceuticals provide mutually complementary data concerning properties of the malignant tissue under examination. This gives the opportunity to estimate both tumor perfusion (82Rb‐chloride) and tumor metabolism (18F‐FDG). The study of 82Rb accumulation/elimination in/out of the tumor based on the analysis of the activity/time curves above the tumor is also of significant interest for diagnostic purposes. Such an attempt was made in (Roelcke et al., 1995) using 82Rb‐chloride, 11Cmethionine, and 18FDG as well as (Valk et al., 1988) using 82Rb‐chloride and 18FDG. But detailed analysis of the obtained activity/time curves has not been carried out by the authors probably due to too long time of 82Rb‐chloride injection and short time of PET scanning. The application of diagnostics with 82Rb‐chloride may be an important independent method in PET investigation of brain, or, in particular, a complementary method to ordinary approaches (Bell et al., 2015; Herholz, 2017) using compounds with 18F, 11C, and 13N, especially in combination with cardiological application of the same generator. The goal of the current research is obtaining more data with 82Rb PET in combination with FDG PET and different diagnostic methods (CT, MRI and angiography). The present study is a pilot study, and more data need to be accumulated.

EXPERIMENTAL

The procedures followed were performed in accordance with the Helsinki Declaration of 1975, as revised in 2008. The Study Protocol, Investigator's Brochure, and Summary of Product Characteristics were approved by the institutional Review Ethics Board of RSCRCT as well as by Federal Service for Surveillance in Healthcare (Roszdravnadzor, Russian Federation). All patients (human subjects) provided written informed consent prior to participation in this study. 82Rb‐generator GR‐01 with package design and 82Rb elution system scheme is shown in Figure 1. The generator described in details in (Chudakov et al., 2014) consists of a generator column encased in a shielding container made of tungsten and steel (Figure 1a). The column contains a parent radionuclide 82Sr (T1/2 = 25.55 d) adsorbed on the ion‐exchange material based on hydrated tin oxide. A daughter radionuclide 82Rb (T1/2 = 76 s) generated as decay product of 82Sr is eluted from the generator in the isotonic solution (0.9% NaCl). Up to 6 GBq (160 mCi) of 82Sr may be loaded into the generator GR‐01. For transportation of 82Sr/82Rb‐generator, a certified package design is used (Figure 1b). The scheme of elution system is shown in Figure 1c (the blue arrow indicates the saline flow direction, and the red arrows indicate the flow direction of eluate with 82Rb‐chloride). A minimum time to perform sequential imaging in studies of patients is 15 min.
Figure 1

(a) 82Sr/82Rb generator GR‐01 (left). (b) Package Design. (c) 82Rb‐chloride radiopharmaceutical elution system scheme: Programmable syringe pump—1; 3‐way stopcock—2; sterilizing filter—3; saline supply—4; plastic extender (tubing with Luer edges)—5; adapter (from Swagelok to Luer)—6; one‐way valve—7; syringe with saline for air removal from the system—8; peripheral venous catheter—9; 82Sr/82Rb generator—10

(a) 82Sr/82Rb generator GR‐01 (left). (b) Package Design. (c) 82Rb‐chloride radiopharmaceutical elution system scheme: Programmable syringe pump—1; 3‐way stopcock—2; sterilizing filter—3; saline supply—4; plastic extender (tubing with Luer edges)—5; adapter (from Swagelok to Luer)—6; one‐way valve—7; syringe with saline for air removal from the system—8; peripheral venous catheter—9; 82Sr/82Rb generator—10 There are three possible elution types of radiopharmaceutical administration: constant‐flow elution, constant‐activity elution, and constant‐time elution. For the administration of the generator‐produced radiopharmaceutical 82Rb‐chloride, we use the constant‐time elution as the most preferable one. As a rule, a stream infusion of the radiopharmaceutical lasts 14 s (the period from 11 to 16 s is acceptable). The volume of eluate per infusion ranges from 5 to 25 ml, and the infusion rate ranges from 3 to 90 ml/min (the usual range is 40–80 ml/min). Provided service conditions, the entire period of the generator operation ranks over all known analogs and certified for 60 days. A possible eluate volume before the critical breakthrough of 82Sr (0.01 kBq/MBq 82Rb) or 85Sr (0.1 kBq/MBq 82Rb) is up to 30 L in GR‐01 generator. 2D positron‐emission tomography “Ecat‐Exact‐HR+” (Siemens AG Germany) was used for the investigations. According to the regular practice, in cardiological tests for diagnostic purpose the administered dose of 82Rb‐chloride ranges from 2,000 to 2,500 MBq. In this research, the diagnostic dose of 82Rb‐chloride radiopharmaceutical in neurooncological patients was defined as about 800 MBq per 1 m2 of patient's body and makes up 820–1,500 MBq per single injection in order to get enough good images with 2D‐scanner. A coefficient for calculating an effective dose is 1.26 μSv/MBq using the tissue‐weighting factor of the International Commission on Radiological Protection (International Commission on Radiological Protection (ICRP), 2008). So, the total effective dose was 1.0–1.9 mSv per single injection in compare, for example, with about 7–9 mSv from injected 18F‐FDG activity 370–450 MBq (Marti‐Climent et al., 2017; Quin, Dauer, Pandit‐Taskar, Scholder, & Dauer, 2016). This fact stimulates using 82Rb‐chloride after application of the same generator in cardiological investigations when 82Sr‐activity in the generator drops down and is too low for obtaining good images in cardiology. Special preparation of patients was not required. Before the examination, 10‐min transmission scanning with 68Ge calibration source was performed for attenuation correction. We performed emission scanning in “2D‐mode” with 128 × 128 matrix and zoom image by 1.5. The scanning was carried out in the dynamic mode: 6 frames at 10 s each, 4 frames at 30 s each, 4 frames at 60 s each, and 2 frames at 120 s each (11 min in total). Total study duration takes approximately 30 min. per one patient (the inclusion period was from 4 February to 18 December 2015). The image reconstruction was done with “Backprojection”‐filter and zoom image by 2.5. The region of interest in the brain reconstructed image was detected according to the data on brain lesion location obtained by structured methods (MRT). Frames starting from the end of bolus elution (1 min) up to the end of the uptake phase were summed (from 7th to 20th frame) in tissue phase. The uptake index (UI) and vascularization degree (VD) were estimated, and activity/time curves for tumors and normal brain cortex areas were plotted. UI is a ratio between maximal activity value accumulated in zone of interest of the tumor and maximal activity value in the zone of interest of the intact brain tissue. VD is a ratio between maximal activity value accumulated in zone of interest of the tumor and maximal activity value in the normal cortex of the vascular phase. A total of 21 patients at the age of 18–76 with different brain tumors were examined. All the patients underwent PET examination with 82Rb‐chloride along with MRT with contrast agent, and some patients underwent PET examination with 18F‐FDG, CT along with brain X‐ray angiography.

RESULTS AND DISCUSSIONS

In 14 of total amount, 21 patients (67%) brain tumors were diagnosed. In 10 of 14 patients, malignant tumors (8 glioblastoma and 2 meningioma) were diagnosed. In other 4 of 14 patients, the benign brain tumors (3 astrocytoma and 1 meningioma) were diagnosed. In 3 of 21 patients, postsurgical cysts and in 4 patients arteriovenous malformations were diagnosed. In all 10 cases, malignant tumors (glioblastoma and meningioma) were exactly visualized at PET examination with 82Rb‐chloride. In all the cases, abnormal focuses of radiopharmaceutical high uptake were detected in the image of a tumor node (Figures 2, 3). Activity/time curves plotted over malignant tumors images (Figure 2) show for high vascularization of the malignant tumors along with pathological permeability of cell membranes of the tumor blood vessels as compared to intact brain cortex. It is noteworthy that as a rule, monotonic increase in radiopharmaceutical's uptake in malignant glioma and meningioma was detected during the whole scan session (11 min) (Figures 2, 3).
Figure 2

(a‐d), Female patient g. Diagnosis: glioblastoma multiforme recurrence growth of the right parietal lobe. (a) At MRI (T2‐weighted image), the tumor is well visible, and perifocal edema is defined. (b) 18F‐FDG PET image demonstrates heterogeneous unsharp mass with the high glycolytic rate glycolysis (UI = 1.0). The lesion is partially visible due to its location in the white matter as well as to edema and ischemization of the adjacent brain cortex. (c) 82Rb‐chloride PET image demonstrates a sharp homogeneous hypervascular focus with high radiopharmaceutical uptake in the tissue phase (UI = 17) (position 1). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve of the lesion (1) shows that the tumor has the high vascularization degree (VD = 2.1). Vascular permeability is impaired. Within the tissue phase, high radiopharmaceutical uptake in tumor exceeds the radiopharmaceutical uptake in the contralateral brain cortex (2) in 17 times. A typical for malignant tumors slow monotonic radiopharmaceutical uptake in the tumor within the tissue phase is observed

Figure 3

(a‐c), Female patient n. Diagnosis: anaplastic meningioma recurrence growth of the posterior cranial fossa on the right. (a) At the CT image, the lesion is not well visualized, and the boundaries are unsharp. (b) 82Rb‐chloride PET image demonstrates a homogeneous mass of hyperfixation with high radiopharmaceutical uptake within the tissue phase (UI = 9.7) (position 1). Contralateral brain cortex is shown in position 2. (c) Activity/Time curve of the tumor (1) shows that the lesion has moderate vascularization. Vascular permeability is impaired. A typical for malignant lesions low monotonic radiopharmaceutical uptake in the lesion within the tissue phase is observed. Relatively low vascularization for a meningioma could be explained by preceded treatment. The activity/time curve (2) over contralateral cortex is shown for comparison

(a‐d), Female patient g. Diagnosis: glioblastoma multiforme recurrence growth of the right parietal lobe. (a) At MRI (T2‐weighted image), the tumor is well visible, and perifocal edema is defined. (b) 18F‐FDG PET image demonstrates heterogeneous unsharp mass with the high glycolytic rate glycolysis (UI = 1.0). The lesion is partially visible due to its location in the white matter as well as to edema and ischemization of the adjacent brain cortex. (c) 82Rb‐chloride PET image demonstrates a sharp homogeneous hypervascular focus with high radiopharmaceutical uptake in the tissue phase (UI = 17) (position 1). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve of the lesion (1) shows that the tumor has the high vascularization degree (VD = 2.1). Vascular permeability is impaired. Within the tissue phase, high radiopharmaceutical uptake in tumor exceeds the radiopharmaceutical uptake in the contralateral brain cortex (2) in 17 times. A typical for malignant tumors slow monotonic radiopharmaceutical uptake in the tumor within the tissue phase is observed (a‐c), Female patient n. Diagnosis: anaplastic meningioma recurrence growth of the posterior cranial fossa on the right. (a) At the CT image, the lesion is not well visualized, and the boundaries are unsharp. (b) 82Rb‐chloride PET image demonstrates a homogeneous mass of hyperfixation with high radiopharmaceutical uptake within the tissue phase (UI = 9.7) (position 1). Contralateral brain cortex is shown in position 2. (c) Activity/Time curve of the tumor (1) shows that the lesion has moderate vascularization. Vascular permeability is impaired. A typical for malignant lesions low monotonic radiopharmaceutical uptake in the lesion within the tissue phase is observed. Relatively low vascularization for a meningioma could be explained by preceded treatment. The activity/time curve (2) over contralateral cortex is shown for comparison Earlier in (Granov et al., 2011, 2012, 1997), we demonstrated that optimal time for PET scanning with 82Rb‐chloride is 11 min. Along with this, in order to obtain correct activity/time curves the radiopharmaceutical should be administrated during 11–16 s which is faster than in (Roelcke et al., 1995) (30–60 s when scanning time is 6 min). Radiopharmaceutical uptake in the tumor node appeared to be low in 3 patients with astrocytoma of a low malignant potential (Figure 4). Tumor imaging in such cases became possible entirely due to the far lower uptake of 82Rb‐chloride in intact brain cortex, and due to this fact, tumors were partially seen (Figure 4). As a rule, within the tissue phase monotonic radiopharmaceutical elimination was observed or radiopharmaceutical content remained at low level. At the same time, high radiopharmaceutical uptake in the tumor was detected in both vascular and tissue phases in the patient with benign meningioma, and this fact may be explained by high vascularization of meningioma.
Figure 4

(a‐d) Male patient i. Diagnosis: astrocytoma of low malignant potential (Gr II). (a) MRI T1 WI image demonstrates a space‐occupying lesions of the anterior convexital parts of the right frontal lobe. (b) 18F‐FDG PET image demonstrates that the lesion is partially visualized due to its white matter location as well as to the perifocal edema, and the level of the glucose metabolism is low (UI = 0.6). (c) 82Rb‐chloride PET image demonstrates the isovascular focus with low radiopharmaceutical uptake (UI = 1.2) in the projection of the lesion continued growth (position 1). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve obtained in 82Rb‐chloride PET shows that the lesion (1) has moderate vascularization degree (VD = 1.6). The fact that radiopharmaceutical uptake is weak and low and radiopharmaceutical does not linger in the tissue phase indirectly points at the low malignant potential of the lesion. The activity/time curve (2) over contralateral cortex is shown for comparison

(a‐d) Male patient i. Diagnosis: astrocytoma of low malignant potential (Gr II). (a) MRI T1 WI image demonstrates a space‐occupying lesions of the anterior convexital parts of the right frontal lobe. (b) 18F‐FDG PET image demonstrates that the lesion is partially visualized due to its white matter location as well as to the perifocal edema, and the level of the glucose metabolism is low (UI = 0.6). (c) 82Rb‐chloride PET image demonstrates the isovascular focus with low radiopharmaceutical uptake (UI = 1.2) in the projection of the lesion continued growth (position 1). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve obtained in 82Rb‐chloride PET shows that the lesion (1) has moderate vascularization degree (VD = 1.6). The fact that radiopharmaceutical uptake is weak and low and radiopharmaceutical does not linger in the tissue phase indirectly points at the low malignant potential of the lesion. The activity/time curve (2) over contralateral cortex is shown for comparison Radiopharmaceutical uptake in postsurgical cysts after tumor eradication was close to its background absorption. Cysts were not visualized on the background of radiopharmaceutical low uptake in the brain cortex. In patients with arteriovenous malformation (AVM), high 82Rb‐chloride uptake was detected only in the vascular phase and it was low in the tissue phase (Figure 5).
Figure 5

(a‐d) Female patient Z. Diagnosis: arteriovenous malformation of the right parietal lobe. (a) MRI (T2‐weighted image) showing that AVM is well visible. (b) The angiography (in sagittal slice) shows that AVM is well visible, a developed vast vasculature of the aneurysm is observed. (c) Under the 82Rb‐chloride PET examination, we observed a heterogeneous hypervascular focus (position 1), that was swell‐visualized within the tissue phase, but the radiopharmaceutical uptake within the vascular phase was low (UI = 1.1–1.2). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve of AVM shows that the malformation has high vascularization degree (VD = 14), but radiopharmaceutical rapid biexponential clearance took place in the tissue phase. The activity/time curve (2) over contralateral cortex is shown for comparison

(a‐d) Female patient Z. Diagnosis: arteriovenous malformation of the right parietal lobe. (a) MRI (T2‐weighted image) showing that AVM is well visible. (b) The angiography (in sagittal slice) shows that AVM is well visible, a developed vast vasculature of the aneurysm is observed. (c) Under the 82Rb‐chloride PET examination, we observed a heterogeneous hypervascular focus (position 1), that was swell‐visualized within the tissue phase, but the radiopharmaceutical uptake within the vascular phase was low (UI = 1.1–1.2). Contralateral brain cortex is shown in position 2. (d) Activity/Time curve of AVM shows that the malformation has high vascularization degree (VD = 14), but radiopharmaceutical rapid biexponential clearance took place in the tissue phase. The activity/time curve (2) over contralateral cortex is shown for comparison An uptake index UI (ratio 82Rb‐uptake in tumor/82Rb‐uptake in normal brain tissue) was estimated in order to carry out the quantification of obtained data. Obtained results of the radiopharmaceutical uptake level in the examined masses are shown in Table 1.
Table 1

Radiopharmaceutical 82Rb‐chloride uptake level in the brain lesions (21 patients in total)

Morphological diagnosisNumber of patientsUptake index (UI) for brain lesions, tissue phase (observed range and average)Vascularization degree (VD) for brain lesions, of vascular phase (observed range and average)
Glioblastoma multiform (GrIV)8 17.9–25.1 21.6 ± 5.3 1.8–2.5 2.07 ± 0.26
Benign astrocytoma3 1.1–1.4 1.25 ± 0.15 1.2–1.7 1.46 ± 0.22
Malignant meningioma (GrIV)2 9.7–11.2 10.5 ± 1.1 2.1–2.2 2.15 ± 0.05
Benign meningioma110.52.5
Arteriovenous malformation (AVM)4 1.2–2.2 1.8 ± 0.45 11.2–17.8 14.5 ± 2.4
Postsurgical cyst3 0.4–1.5 0.7 ± 0.6 0.4–1.0 0.47 ± 0.17

UI is a ratio between maximal activity value accumulated in zone of interest of the tumor and maximal activity value in the zone of interest of the intact brain tissue. VD is a ratio between activity value accumulated in region of interest in the tumor and activity value in the intact brain tissue of vascular phase.

Radiopharmaceutical 82Rb‐chloride uptake level in the brain lesions (21 patients in total) UI is a ratio between maximal activity value accumulated in zone of interest of the tumor and maximal activity value in the zone of interest of the intact brain tissue. VD is a ratio between activity value accumulated in region of interest in the tumor and activity value in the intact brain tissue of vascular phase. The data represented in Table 1 show that the high 82Rb‐chloride uptake (in UI units) was observed in malignant tumors. On average, UI found in malignant tumors was 19.2 ± 5.8, while in benign glioma and postsurgical cysts the radiopharmaceutical uptake was significantly lower (Student's coefficient p < 0.05). The high radiopharmaceutical uptake in malignant glioma made it possible to rule them out from astrocytoma of low malignant potential (p < 0.05). A distinct direct correlation was revealed (Spearman Rank r = 0.79) between the perfusion level and malignancy grade of the glial tumor under PET investigation with 82Rb‐chloride. The high uptake of 82Rb‐chloride in both malignant and benign meningiomas was observed due to the fact of their high vascularization. Therefore, the high radiopharmaceutical uptake in malignant glioma and low radiopharmaceutical uptake in benign glioma are associated with the tumor vascularization grade. The fact makes it possible to use PET examination with 82Rb‐chloride for differential diagnostics between malignant and benign glioma. It also gives the opportunity not only to image malignant lesions but also to rate glial lesions according to their malignant grade. 82Rb‐chloride is a nonspecific radiopharmaceutical, and for this reason, the level of its uptake by the tumor primarily depends on the tumor vascularization. This fact was demonstrated in comparison with malignant and benign gliomas: it was possible to differentiate between benign and malignant gliomas. The high radiopharmaceutical uptake in benign meningioma made it impossible to differentiate between benign and malignant meningiomas. However, this problem can be easily solved by successive using 18F‐FDG which does not accumulate in benign tumors. Also, the differential diagnostics of meningioma is generally made during MRI examination. An important problem is what mechanisms could contribute to 82Rb accumulation in brain tumors. The level of 82Rb‐uptake in tumor directly depends on its vascularization rate, integrity of blood‐brain barrier (BBB), and sodium–potassium pump efficiency. Vascularization, BBB disruption, and efficiency of sodium–potassium pump are considerably higher in malignant tumors in comparison with benign tumors. Thus, Rb (as an analogue of potassium) penetrates BBB from extracellular fluid and is more easily retained in cells in comparison with benign glioma, especially if the pump functioning is incorrect. This may be a reason for 82Rb hyperfixation and incorrect functioning of the pump. A detailed future study with more quantitation of images will provide more efficient application of 82Rb‐chloride pharmaceutical in neurooncology.

CONCLUSION

Application of radiopharmaceutical 82Rb‐chloride from 82Sr/82Rb generator demonstrates a possibility of diagnostics different tumor and nontumor lesions, such as AVM, in human brain with low radiation effective doses (1.0–1.9 mSv). Uptake index and activity/time curve analysis in constant‐elution time mode with short‐lived 82Rb (T1/2 = 76 s) provide evaluation of vascularization in tumors and malignancy of gliomas. A low diagnostic dose acceptable in neurooncological studies (up to 820 MBq with 2D‐scanner) makes it possible to use 82Sr/82Rb generator during a long period (60 days certified for generator GR‐01), in particular, after cardiological studies with the same generator.

CONFLICT OF INTERESTS

The authors have no conflict of interests to declare.
  15 in total

1.  Association of rubidium and C-methionine uptake in brain tumors measured by positron emission tomography.

Authors:  U Roelcke; E Radü; S Ametamey; R Pellikka; W Steinbrich; K L Leenders
Journal:  J Neurooncol       Date:  1996-02       Impact factor: 4.130

2.  Extracardiac abnormalities on rubidium-82 cardiac positron emission tomography/computed tomography.

Authors:  Sahar Mirpour; Amir H Khandani
Journal:  Nucl Med Commun       Date:  2011-04       Impact factor: 1.690

3.  Nonuniformity artifact mimicking extracardiac uptake on rubidium-82 myocardial perfusion image.

Authors:  Sameer Kale; Raghuveer Halkar; James Galt
Journal:  Clin Nucl Med       Date:  2007-04       Impact factor: 7.794

4.  The use of inorganic exchangers to improve the 82Sr-82Rb generator.

Authors:  S Kulprathipanja; D J Hnatowich; R Beh
Journal:  Int J Appl Radiat Isot       Date:  1979-07

5.  Alteration of blood-brain barrier in human brain tumors: comparison of [18F]fluorodeoxyglucose, [11C]methionine and rubidium-82 using PET.

Authors:  U Roelcke; E W Radü; K von Ammon; O Hausmann; R P Maguire; K L Leenders
Journal:  J Neurol Sci       Date:  1995-09       Impact factor: 3.181

6.  Brain tumor evaluation using Rb-82 and positron emission tomography.

Authors:  C K Yen; Y Yano; T F Budinger; R P Friedland; S E Derenzo; R H Huesman; H A O'Brien
Journal:  J Nucl Med       Date:  1982-06       Impact factor: 10.057

7.  Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging.

Authors:  Hanna Järnum; Elena G Steffensen; Linda Knutsson; Ernst-Torben Fründ; Carsten Wiberg Simonsen; Søren Lundbye-Christensen; Ajit Shankaranarayanan; David C Alsop; Finn Taagehøj Jensen; Elna-Marie Larsson
Journal:  Neuroradiology       Date:  2009-10-20       Impact factor: 2.804

Review 8.  Clinical applications of PET/MRI: current status and future perspectives.

Authors:  Felix Nensa; Karsten Beiderwellen; Philipp Heusch; Axel Wetter
Journal:  Diagn Interv Radiol       Date:  2014 Sep-Oct       Impact factor: 2.630

9.  Quantitative measurement of blood-brain barrier permeability using rubidium-82 and positron emission tomography.

Authors:  D J Brooks; R P Beaney; A A Lammertsma; K L Leenders; P L Horlock; M J Kensett; J Marshall; D G Thomas; T Jones
Journal:  J Cereb Blood Flow Metab       Date:  1984-12       Impact factor: 6.200

Review 10.  Story of Rubidium-82 and Advantages for Myocardial Perfusion PET Imaging.

Authors:  Jean-François Chatal; François Rouzet; Ferid Haddad; Cécile Bourdeau; Cédric Mathieu; Dominique Le Guludec
Journal:  Front Med (Lausanne)       Date:  2015-09-11
View more
  1 in total

Review 1.  The Chemical Scaffold of Theranostic Radiopharmaceuticals: Radionuclide, Bifunctional Chelator, and Pharmacokinetics Modifying Linker.

Authors:  Holis Abdul Holik; Faisal Maulana Ibrahim; Angela Alysia Elaine; Bernap Dwi Putra; Arifudin Achmad; Achmad Hussein Sundawa Kartamihardja
Journal:  Molecules       Date:  2022-05-10       Impact factor: 4.927

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.