| Literature DB >> 30727982 |
Ahmed A M Gad1, Bahaa-Eldin Hasan Abdulhalim2, Ayman Lotfy3, Ayman Mohamed Abdelrahman3, Ahmed Samir Ahmed3.
Abstract
BACKGROUND: To study the efficacy of the biodegradable collagen implant Ologen® as an adjuvant in phaco-viscocanalostomy in patients with coexisting cataract and primary open angle glaucoma.Entities:
Keywords: Glaucoma; Ologen; Phacoemulsification; Viscocanalostomy
Mesh:
Substances:
Year: 2019 PMID: 30727982 PMCID: PMC6364460 DOI: 10.1186/s12886-019-1049-6
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Deep flap dissection. a Blunt dissection of deep scleral flap with microsponge to make a Descematic window. b Removal of deep flap by Vannas scissors
Fig. 2Ologen insertion. Insertion of the biodegradable Ologen® implant at the site of the removed deep scleral flap
Demographic and preoperative data, and follow-up period of the studied groups
| Parameters | Phaco-viscocanalostomy group ( | Phaco-viscocanalostomy with Ologen® implant group ( | |
|---|---|---|---|
| Age; yrs | |||
| Range | 40–81 | 41–79 | |
| Mean ± SD | 57.95 ± 9.61 | 58.18 ± 9.00 | 0.91† |
| Sex; n (%) | |||
| Male | 16 (41.0) | 17 (42.5) | |
| Female | 23 (59.0) | 23 (57.5) | 0.89‡ |
| Visual acuity | |||
| Range | 0.1–0.7 | 0.1–0.6 | |
| mean ± SD | 0.41 ± 0.18 | 0.37 ± 0.17 | 0.33† |
| IOPa; mmHg | |||
| Range | 15–25 | 15–26 | |
| mean ± SD | 19.46 ± 3.26 | 19.18 ± 3.19 | 0.69† |
| Antiglaucoma drugs; n | |||
| Range | 2–4 | 2–4 | |
| mean ± SD | 2.85 ± 0.87 | 2.88 ± 0.91 | 0.70§ |
IOP intraocular pressure, SD standard deviation
ameasured with treatment
†Two-tailed student t test
‡Chi square test
§Man-Whitney U test
Intraocular pressure (mmHg) results in cases with goniopuncture
| Parameters | Phaco-viscocanalostomy group ( | Phaco-viscocanalostomy with Ologen® implant group ( | |
|---|---|---|---|
| IOP pre-goniopuncture | |||
| Range | 22–45 | 22–44 | |
| mean ± SD | 28.10 ± 6.39 | 28.73 ± 6.29 | 0.76 |
| Number of shots | |||
| Range | 8–16 | 2–9 | |
| mean ± SD | 11.47 ± 2.25 | 5.23 ± 1.85 | < 0.001 |
| IOP post-goniopuncture | |||
| Range | 15–30 | 12–30 | |
| mean ± SD | 21.95 ± 4.04 | 18.68 ± 5.40 | 0.03 |
| Changes of IOP, mean ± SD | −6.14 ± 6.59 | −10.05 ± 4.02 | 0.03 |
IOP intraocular pressure, SD standard deviation
*Two-tailed student t test
Preoperative and 2 years postoperative results
| Parameters | Phaco-viscocanalostomy group ( | Phaco-viscocanalostomy with Ologen® implant group ( | ||||
|---|---|---|---|---|---|---|
| Preoperative | Postoperative | Preoperative | Postoperative | |||
| Visual acuity | ||||||
| Range | 0.1–0.7 | 0.5–1.0 | 0.1–0.6 | 0.5–1.0 | ||
| mean ± SD | 0.41 ± 0.18 | 0.75 ± 0.18 | < 0.001† | 0.37 ± 0.17 | 0.73 ± 0.19 | < 0.001† |
| IOPa; mmHg | ||||||
| Range | 15–25 | 15–22 | 14–26 | 13–21 | ||
| mean ± SD | 19.46 ± 3.26 | 16.85 ± 1.58 | < 0.001† | 19.18 ± 3.19 | 15.96 ± 1.79 | < 0.001† |
| Antiglaucoma drugs; n | ||||||
| Range | 2–4 | 0–4 | 2–4 | 0–4 | ||
| mean ± SD | 2.85 ± 0.87 | 0.64 ± 1.01 | < 0.001‡ | 2.88 ± 0.91 | 0.35 ± 0.86 | < 0.001‡ |
IOP intraocular pressure, SD standard deviation
ameasured with treatment
†One-tailed student t test
‡Man-Whitney U test
Results 2 years postoperatively
| Parameters | Phaco-viscocanalostomy group ( | Phaco-viscocanalostomy with Ologen® implant group ( | |
|---|---|---|---|
| Visual acuity | |||
| Range | 0.5–1.0 | 0.5–1.0 | |
| mean ± SD | 0.75 ± 0.18 | 0.73 ± 0.19 | 0.63† |
| IOPa; mmHg | |||
| Range | 15–22 | 13–21 | |
| mean ± SD | 16.85 ± 1.58 | 15.96 ± 1.79 | 0.02† |
| Antiglaucoma drugs; n | |||
| Range | 0–4 | 0–4 | |
| mean ± SD | 0.64 ± 1.01 | 0.35 ± 0.86 | 0.06‡ |
| Success results | |||
| complete success, n (%) | 23 (59.0) | 32 (80.0) | 0.04§ |
| qualified success, n (%) | 12 (30.8) | 5 (12.5) | 0.048§ |
| failure, n (%) | 4 (10.3) | 3 (7.5) | 0.67§ |
IOP intraocular pressure, SD standard deviation
ameasured without treatment
†Two-tailed student t test
‡Man-Whitney U test
§Chi square test