Literature DB >> 30724814

Compressed Sensing and Parallel Imaging for Double Hepatic Arterial Phase Acquisition in Gadoxetate-Enhanced Dynamic Liver Magnetic Resonance Imaging.

Ja Kyung Yoon1, Myeong-Jin Kim, Sunyoung Lee.   

Abstract

OBJECTIVES: The aim of this study was to investigate the utility of a combined compressed sensing and parallel imaging (C-SENSE) technique for single breath-hold, double arterial phase (AP) examinations in gadoxetate-enhanced magnetic resonance imaging (MRI) of the liver.
MATERIALS AND METHODS: We retrospectively reviewed single breath-hold, double AP images obtained by using a C-SENSE technique for gadoxetate-enhanced dynamic liver MRI in a total of 127 patients (89 men and 38 women; mean age, 62.6 ± 7.5 [range, 29-87] years). For qualitative analysis, 3 readers independently scored the timing of the AP images, degree of artifacts, and overall image quality on both the first and second AP images (AP1 and AP2, respectively). The combined scores of AP1 and AP2 (AP1 + AP2) were determined by using the better scores from the 2 sets. Focal lesion detectability was assessed for 124 lesions with arterial enhancement on AP1 and AP2, and on simultaneous review of both AP1 and AP2. Then, in 62 patients whose previous gadoxetate-enhanced single AP images were available, AP timing and overall image quality were compared between single and double AP images. Wilcoxon signed rank test was performed for each comparison. Fleiss kappa value was calculated for analysis of interreader agreement.
RESULTS: Optimal AP timing was achieved in 86% of AP1, 65% of AP2, and 90% of AP1 + AP2 images; results were significantly better for AP1 and AP1 + AP2 images than for AP2 images (P < 0.001 for both comparisons). Respiratory motion artifacts were negligible in 73% of the AP1 + AP2 images, which was significantly better than the corresponding values for the AP1 (61%, P < 0.001) or AP2 (50%, P < 0.001) images. Overall image quality was significantly better for AP1 + AP2 (excellent in 54%) than for AP1 (49%, P < 0.001) or AP2 (39%, P < 0.001) images. Lesion detectability was comparable between AP1 and AP2 images and was significantly better on AP1 + AP2. Comparison of single and double AP imaging techniques showed better AP timing (P = 0.004) and fewer respiratory motion artifacts (P < 0.001) for AP1 + AP2 than for the single AP images.
CONCLUSIONS: The C-SENSE technique may facilitate single breath-hold, double AP imaging with optimal timing and reduced respiratory motion artifacts in gadoxetate-enhanced dynamic MRI of the liver.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30724814     DOI: 10.1097/RLI.0000000000000548

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

1.  Evaluation of liver tumor identification rate of volumetric-interpolated breath-hold images using the compressed sensing method and qualitative evaluation of tumor contrast effect via visual evaluation.

Authors:  Daisuke Yoshimaru; Yoich Araki; Chifumi Matsuda; Natsuhiko Shirota; Yu Tajima; Shuhei Shibukawa; Katsutoshi Murata; Dominik Nickel; Kazuhiro Saito
Journal:  Quant Imaging Med Surg       Date:  2022-05

2.  Clinical feasibility of ultrafast intracranial vessel imaging with non-Cartesian spiral 3D time-of-flight MR angiography at 1.5T: An intra-individual comparison study.

Authors:  Thomas Sartoretti; Elisabeth Sartoretti; Árpád Schwenk; Luuk van Smoorenburg; Manoj Mannil; André Euler; Anton S Becker; Alex Alfieri; Arash Najafi; Christoph A Binkert; Michael Wyss; Sabine Sartoretti-Schefer
Journal:  PLoS One       Date:  2020-04-29       Impact factor: 3.240

3.  Quantitative evaluation of focal liver lesions with T1 mapping using a phase-sensitive inversion recovery sequence on gadoxetic acid-enhanced MRI.

Authors:  Motohira Mio; Yasuhiro Fujiwara; Kazuki Tani; Tatsuo Toyofuku; Toshihiro Maeda; Toshiro Inoue
Journal:  Eur J Radiol Open       Date:  2020-12-24

Review 4.  MR Imaging in the 21st Century: Technical Innovation over the First Two Decades.

Authors:  Hiroyuki Kabasawa
Journal:  Magn Reson Med Sci       Date:  2021-04-16       Impact factor: 2.760

5.  Compressed SENSE in Pediatric Brain Tumor MR Imaging : Assessment of Image Quality, Examination Time and Energy Release.

Authors:  Rieke L Meister; Michael Groth; Julian H W Jürgens; Shuo Zhang; Jan H Buhk; Jochen Herrmann
Journal:  Clin Neuroradiol       Date:  2022-01-07       Impact factor: 3.156

6.  Contrast-Enhanced High-Resolution Intracranial Vessel Wall MRI with Compressed Sensing: Comparison with Conventional T1 Volumetric Isotropic Turbo Spin Echo Acquisition Sequence.

Authors:  Chae Jung Park; Jihoon Cha; Sung Soo Ahn; Hyun Seok Choi; Young Dae Kim; Hyo Suk Nam; Ji Hoe Heo; Seung Koo Lee
Journal:  Korean J Radiol       Date:  2020-08-04       Impact factor: 3.500

7.  Clinical Evaluation of an Abbreviated Contrast-Enhanced Whole-Body MRI for Oncologic Follow-Up Imaging.

Authors:  Judith Herrmann; Saif Afat; Andreas Brendlin; Maryanna Chaika; Andreas Lingg; Ahmed E Othman
Journal:  Diagnostics (Basel)       Date:  2021-12-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.