Literature DB >> 30724114

Changes in acetabular component alignment due to screw fixation in patients with hip dysplasia.

Tomonori Tetsunaga1, Kazuo Fujiwara2, Hirosuke Endo1, Tomoko Tetsunaga1, Takamasa Miyake1, Kazuki Yamada1, Tomoaki Sanki1, Toshifumi Ozaki1.   

Abstract

INTRODUCTION: Adequate initial stability of the acetabular cup is essential for total hip arthroplasty (THA). However, changes in the alignment of the acetabular component caused by screw fixation are concerning in patients with inadequate bone stock. This study aimed to investigate the effects of screw fixation on the alignment of the acetabular component in THA patients with hip dysplasia.
METHODS: We retrospectively examined 256 hips (range 28-87 years) that underwent THA using a navigation system. Patients were divided into 2 groups based on the presence or absence of changes in the alignment of the intraoperative acetabular cup, and univariate and multivariate analyses were performed to identify factors that were predictive of changes in acetabular component alignment after screw fixation in 2 dimensions: inclination and anteversion.
RESULTS: Screw fixation led to a mean change in inclination of 1.6° (range 0-10°) and a mean change in anteversion of 1.4° (range 0-14°). The Crowe classification, the presence of bone cysts, and the use of an inferior quadrant screw were identified as factors that correlated with acetabular cup alignment changes in inclination (odds ratios, 6.01, 5.94 and 0.03, respectively). Only the Crowe classification was identified as a factor that correlated with intraoperative alignment changes in anteversion (odds ratio, 2.08).
CONCLUSIONS: Screw fixation altered the acetabular cup alignment. The inclination changes were related to the extent of the dysplasia, and the risk was reduced when the inferior quadrant screw was used. Surgeons should use caution during screw fixation in THAs performed on severely dysplastic hips.

Entities:  

Keywords:  Anteversion; inclination; navigation system; screw; total hip arthroplasty

Mesh:

Year:  2019        PMID: 30724114     DOI: 10.1177/1120700019828708

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Accuracy of acetabular cup insertion in an anterolateral supine approach using an accelerometer-based portable navigation system.

Authors:  Masahiro Hasegawa; Yohei Naito; Shine Tone; Hiroki Wakabayashi; Akihiro Sudo
Journal:  J Artif Organs       Date:  2020-09-02       Impact factor: 1.731

2.  A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report.

Authors:  Antonio Murcia-Asensio; Francisco Ferrero-Manzanal; Pablo Sanz-Ruiz; Hermenegildo Cañada-Oya; Raquel Lax-Pérez; Christian Goetze
Journal:  Case Rep Orthop       Date:  2022-06-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.