Literature DB >> 30719539

The Efficacy of Paclitaxel Drug-Eluting Balloon Angioplasty Versus Standard Balloon Angioplasty in Stenosis of Native Hemodialysis Arteriovenous Fistulas: An Analysis of Clinical Success, Primary Patency and Risk Factors for Recurrent Dysfunction.

Isil Yildiz1.   

Abstract

PURPOSE: To investigate the efficacy of paclitaxel drug-eluting balloons (PEB) versus standard balloon angioplasty (BA) in stenosis of native hemodialysis arteriovenous fistulas (AVFs).
MATERIALS AND METHODS: A total of 96 patients with ESRD (mean ± SD age 57.0 ± 9.1 years, 63.5% were males) who underwent endovascular treatment with PEB angioplasty (n = 32) and BA (n = 64) for a dysfunctional native AVF were included. Clinical success, complications, primary patency and postoperative recurrence parameters were recorded in each group.
RESULTS: Primary patency rate at 6 months was significantly higher in PEB than in BA group (96.9 vs. 20.3%, p < 0.001), while the two groups had similar primary patency rates at 9 months (66.8 vs. 50.0%) and 12 months (6.3% for each). No significant difference was noted between PEB and BA groups in terms of the rate (21.9% and. 31.3%), time (median 220 vs. 152.5 days) and reasons (reocclusion in 18.8 vs. 28.1%) for dysfunction recurrence as well as the number of recurrent treatments. AVF dysfunction recurrence was more likely in younger age AVF (median 4 vs. 23 months, p < 0.001 in PEB, and 8.5 vs. 20.5 months p = 0.001 in SBA) and in AVF ≤ 6 months in both SBA and PEB groups (71.4 vs. 12.0%, p = 0.005 in PEB, 40.0 vs. 2.3%, p < 0.001).
CONCLUSION: In conclusion, our findings emphasize favorable safety and efficacy of PEB and BA in the management of dysfunctional hemodialysis AVFs with similar rates of post-PTA recurrence of AVF dysfunction. Nonetheless, there was a nonsignificant tendency for lower rate and a delay for recurrent dysfunction in patients treated with PEB and a significant association younger AVF age with an increased risk of post-PTA recurrence of AVF dysfunction. LEVEL OF EVIDENCE: 3, Retrospective cohort study.

Entities:  

Keywords:  Arteriovenous fistula; Clinical success; Hemodialysis; Paclitaxel drug-eluting balloon angioplasty; Primary patency; Recurrent dysfunction; Standard balloon angioplasty

Mesh:

Substances:

Year:  2019        PMID: 30719539     DOI: 10.1007/s00270-019-02171-3

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

1.  Paclitaxel coated balloon versus conventional balloon angioplasty in dysfunctional dialysis arteriovenous fistula: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Chuxuan Luo; Mingzhu Liang; Yueming Liu; Danna Zheng; Qiang He; Juan Jin
Journal:  Ren Fail       Date:  2022-12       Impact factor: 2.606

2.  Drug-eluting balloon (DEB) versus plain old balloon angioplasty (POBA) in the treatment of failing dialysis access: A prospective randomized trial.

Authors:  Torbjörn Fransson; Anders Gottsäter; Mohammad Abdulrasak; Martin Malina; Timothy Resch
Journal:  J Int Med Res       Date:  2022-03       Impact factor: 1.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.