Coefficient of variation of P-wave duration measured using an automated measurement system predicts recurrence of atrial fibrillation.

Yosuke Nakatani1, Tamotsu Sakamoto2, Yoshiaki Yamaguchi2, Yasushi Tsujino2, Naoya Kataoka2, Koichiro Kinugawa2.   

Abstract

BACKGROUND: P-wave parameters representing atrial conduction heterogeneity are associated with recurrence of atrial fibrillation (AF) after catheter ablation. However, intra- and inter-observer variabilities are unavoidable during manual measurement of P-wave parameters.
METHODS: The study included 201 patients with paroxysmal AF who underwent catheter ablation. P-wave duration (PWD) was measured using a computerized automated measurement system with a surface 12-lead electrocardiogram. The coefficient of variation of PWD (CV-PWD) across the 12 electrocardiographic leads was determined as an index of atrial conduction heterogeneity.
RESULTS: AF did not recur in 157 (78%) patients during a 12-month follow-up period. CV-PWD assessed before catheter ablation was not different between the AF-recurrent and AF-free groups (0.069 ± 0.023 vs. 0.069 ± 0.023, P = 0.090). However, CV-PWD measured after catheter ablation was significantly larger in the AF-recurrent group than in the AF-free group (0.090 ± 0.037 vs. 0.073 ± 0.024, P < 0.001). In receiver operating curve analysis, CV-PWD assessed after catheter ablation achieved an area under the curve of 0.702; the sensitivity, specificity, and positive and negative predictive values were 68%, 69%, 38%, and 88%, respectively, for the cut-off value of 0.080. During the follow-up period, AF freedom rates of high CV-PWD patients (CV-PWD ≥ 0.080) and low CV-PWD patients (CV-PWD < 0.080) were 65% and 88%, respectively.
CONCLUSIONS: CV-PWD determined using an automated measurement system was associated with AF recurrence after catheter ablation in patients with paroxysmal AF.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Atrial conduction heterogeneity; Atrial fibrillation; Atrial remodeling; Catheter ablation; P-wave duration

Mesh:

Year:  2019        PMID: 30716526     DOI: 10.1016/j.jelectrocard.2019.01.089

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  2 in total

1.  P-Wave Beat-to-Beat Analysis to Predict Atrial Fibrillation Recurrence after Catheter Ablation.

Authors:  Dimitrios Tachmatzidis; Anastasios Tsarouchas; Dimitrios Mouselimis; Dimitrios Filos; Antonios P Antoniadis; Dimitrios N Lysitsas; Nikolaos Mezilis; Antigoni Sakellaropoulou; Georgios Giannopoulos; Constantinos Bakogiannis; Konstantinos Triantafyllou; Nikolaos Fragakis; Konstantinos P Letsas; Dimitrios Asvestas; Michael Efremidis; Charalampos Lazaridis; Ioanna Chouvarda; Vassilios P Vassilikos
Journal:  Diagnostics (Basel)       Date:  2022-03-28

2.  Characterization of Changes in P-Wave VCG Loops Following Pulmonary-Vein Isolation.

Authors:  Nuria Ortigosa; Óscar Cano; Frida Sandberg
Journal:  Sensors (Basel)       Date:  2021-03-09       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.