Literature DB >> 30716042

Long-Term Functionality of Transversal Intraneural Electrodes Is Improved By Dexamethasone Treatment.

N de la Oliva, J Del Valle, I Delgado-Martinez, M Mueller, T Stieglitz, Xavier Navarro.   

Abstract

Neuroprostheses aimed to restore lost functions after a limb amputation are based on the interaction with the nervous system by means of neural interfaces. Among the different designs, intraneural electrodes implanted in peripheral nerves represent a good strategy to stimulate nerve fibers to send sensory feedback and to record nerve signals to control the prosthetic limb. However, intraneural electrodes, as any device implanted in the body, induce a foreign body reaction (FBR) that results in the tissue encapsulation of the device. The FBR causes a progressive decline of the electrode functionality over time due to the physical separation between the electrode active sites and the axons to interface. Modulation of the inflammatory response has arisen as a good strategy to reduce the FBR and maintain electrode functionality. In this study transversal intraneural multi-channel electrodes (TIMEs) were implanted in the rat sciatic nerve and tested for 3 months to evaluate stimulation and recording capabilities under chronic administration of dexamethasone. Dexamethasone treatment significantly reduced the threshold for evoking muscle responses during the follow-up compared to saline-treated animals, without affecting the selectivity of stimulation. However, dexamethasone treatment did not improve the signal-to-noise ratio of the recorded neural signals. Dexamethasone treatment allowed to maintain more working active sites along time than saline treatment. Thus, systemic administration of dexamethasone appears as a useful treatment in chronically implanted animals with neural electrodes as it increases the number of functioning contacts of the implanted TIME and reduces the intensity needed to stimulate the nerve.

Entities:  

Year:  2019        PMID: 30716042     DOI: 10.1109/TNSRE.2019.2897256

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  3 in total

1.  Ultrasound-Guided Transversus Abdominis Plane Block for Cesarean Delivery: Injection Site Pain as a New Complication and Dexamethasone Reduced Incidence.

Authors:  Hai-Lin Liu; Rui-Hao Zhou; He-Guo Luo; Li-Li Luo; Xue Yuan; Ling Ye
Journal:  J Pain Res       Date:  2020-03-19       Impact factor: 3.133

2.  Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics.

Authors:  Alejandro Carnicer-Lombarte; Shao-Tuan Chen; George G Malliaras; Damiano G Barone
Journal:  Front Bioeng Biotechnol       Date:  2021-04-15

Review 3.  Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review.

Authors:  Kadir A Yildiz; Alexander Y Shin; Kenton R Kaufman
Journal:  J Neuroeng Rehabil       Date:  2020-03-10       Impact factor: 4.262

  3 in total