Literature DB >> 30714713

Facile Fabrication of Surface-Imprinted Macroporous Films for Chemosensing of Human Chorionic Gonadotropin Hormone.

Marcin Dąbrowski1, Agnieszka Zimińska1,2, Jakub Kalecki1, Maciej Cieplak1, Wojciech Lisowski1, Radosław Maksym3, Shuai Shao4, Francis D'Souza4, Alexander Kuhn5, Piyush S Sharma1.   

Abstract

We present an improved approach for the preparation of highly selective and homogeneous molecular cavities in molecularly imprinted polymers (MIPs) via the combination of surface imprinting and semi-covalent imprinting. Toward that, first, a colloidal crystal mold was prepared via the Langmuir-Blodgett (LB) technique. Then, human chorionic gonadotropin (hCG) template protein was immobilized on the colloidal crystal mold. Later, hCG derivatization with electroactive functional monomers via amide chemistry was performed. In a final step, optimized potentiostatic polymerization of 2,3'-bithiophene enabled depositing an MIP film as the macroporous structure. This synergistic strategy resulted in the formation of molecularly imprinted cavities exclusively on the internal surface of the macropores, which were accessible after dissolution of silica molds. The recognition of hCG by the macroporous MIP film was transduced with the help of electric transducers, namely, extended-gate field-effect transistors (EG-FET) and capacitive impedimetry (CI). These readout strategies offered the ability to create chemosensors for the label-free determination of the hCG hormone. Other than the simple confirmation of pregnancy, hCG assay is a common tool for the diagnosis and follow-up of ectopic pregnancy or trophoblast tumors. Concentration measurements with these EG-FET and CI-based devices allowed real-time measurements of hCG in the range of 0.8-50  and 0.17-2.0 fM, respectively, in 10 mM carbonate buffer (pH = 10). Moreover, the selectivity of chemosensors with respect to protein interferences was very high.

Entities:  

Keywords:  capacitive impedimetry; chemosensor; extended-gate field-effect transistor; human chorionic gonadotropin hormone; macroporous electrodes; molecularly imprinted polymer; semi-covalent imprinting

Mesh:

Substances:

Year:  2019        PMID: 30714713     DOI: 10.1021/acsami.8b17951

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  2 in total

1.  Nanogold/graphene as sensing platform coupled with ferrocene/gold as signal amplifier for sandwich-like voltammetric immunosensor of human chorionic gonadotropin.

Authors:  Zhihui Wu; Heng Xue; Miao Zheng; Huiyu Chen; Guolong Chen; Liangpu Xu
Journal:  Am J Transl Res       Date:  2022-06-15       Impact factor: 3.940

Review 2.  Oriented Immobilization of Protein Templates: A New Trend in Surface Imprinting.

Authors:  Jakub Kalecki; Zofia Iskierko; Maciej Cieplak; Piyush S Sharma
Journal:  ACS Sens       Date:  2020-11-22       Impact factor: 7.711

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.