Comparison of Four Electronic Apex Locators in Detecting Working Length: An Ex Vivo Study.

Mehmet Yolagiden1, Seyda Ersahan2, Gokhan Suyun3, Erturk Bilgec1, Cumhur Aydin4.   

Abstract

AIM: To compare the accuracy of four different electronic apex locators (EALs) in detecting a position 0.5 mm short of the major foramen.
MATERIALS AND METHODS: The actual working length of thirty-five extracted human teeth was determined visually as 0.5 mm short of the apical foramen. After actual working length measurements, electronic working length was measured with four different EALs (Apex Pointer+, Raypex 5, Apex ID, and Raypex 6). Measurements were repeated three times by different operators. The data were analyzed using the intraclass correlation coefficient (ICC), the repeated measure analysis of variance (rANOVA) and Bonferroni post hoc tests. The significance level was set at p < 0.05.
RESULTS: The mean differences between electronic and actual working length were-0.305 mm, 0.098 mm, 0.037, and 0.144 mm for the Apex Pointer+, the Raypex 5, the Apex ID, and the Raypex 6, respectively. Multiple paired comparisons (Bonferroni test) also showed the Apex Pointer+ is significantly different from the Raypex 5, Apex ID and Raypex 6 (p = 0.000, p = 0.001, and p = 0.001 respectively).
CONCLUSION: All EALs showed an acceptable determination of the working length between the ranges of ± 0.5mm except for the Apex Pointer+ device, which had the lowest accuracy. Further studies may be beneficial especially to better evaluate the accuracy of the Apex Pointer+. CLINICAL SIGNIFICANCE: This article shows that Apex ID, which has only recently been introduced into the market, showed an acceptable determination of the working length. Its accuracy was similar to that of Raypex 5 and 6.

Entities:  

Keywords:  Apex ID; Apex Pointer+; Apical constriction; Electronic apex locator; Raypex 5; Raypex 6 Working length determination.

Mesh:

Year:  2018        PMID: 30713168

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  3 in total

1.  Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ, Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph-In Vitro Study.

Authors:  Okba Mahmoud; Mawada Hassan Awad Abdelmagied; Ahmad Hisham Dandashi; Bakr Nssaief Jasim; Hussam Alddin Tawfik Kayali; Saaid Al Shehadat
Journal:  Int J Dent       Date:  2021-05-04

2.  The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators.

Authors:  Ewa Marek; Ryta Łagocka; Katarzyna Kot; Krzysztof Woźniak; Mariusz Lipski
Journal:  BMC Oral Health       Date:  2019-12-31       Impact factor: 2.757

3.  Apical periodontitis after intense bruxism.

Authors:  Madline P Gund; Karl-Thomas Wrbas; Matthias Hannig; Stefan Rupf
Journal:  BMC Oral Health       Date:  2022-03-24       Impact factor: 2.757

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.