Literature DB >> 30711322

A solid phase microextraction Arrow with zirconium metal-organic framework/molybdenum disulfide coating coupled with gas chromatography-mass spectrometer for the determination of polycyclic aromatic hydrocarbons in fish samples.

Yongli Yuan1, Xiaoting Lin1, Tianhua Li1, Tianyu Pang1, Youren Dong1, Rongjie Zhuo1, Qiqin Wang2, Yuting Cao1, Ning Gan3.   

Abstract

Solid phase microextraction (SPME) Arrows with enlarged sorption phases and Arrow-shaped tips are good alternatives to classic SPME fibers. Developing SPME Arrows with functionalized coatings has become a growing area of SPME research. In this study, a zirconium metal organic framework/molybdenum disulfide (UiO-66/MoS2) composite coating modified SPME Arrow was developed and coupled with gas chromatography-mass spectrometry for the headspace extraction and detection of 16 polycyclic aromatic hydrocarbons (PAHs). The coating preparation can be easily manipulated by the assembly strategy using silicone gels to adhere UiO-66/MoS2 powder onto the surface of the Arrows. The prepared UiO-66/MoS2 coated SPME Arrows exhibited clearly enhanced adsorption capacity (2.1-4.5 folds) and an improved degree of affinity to PAHs species when compared to commercial PDMS/CARS/DVB SPME Arrows or fibers. The improved mechanism may be due to the high specific area, hierarchical micropores and mesopores, and the largely increased and immobilized amount of UiO-66/MoS2 coating on the stainless-steel Arrow. Under optimized conditions, the SPME Arrow-based assay was successfully applied to determine PAH levels in fish samples with satisfactory recoveries of 80.2-101% and relative standard deviations (RSDs) of less than 6%. The detection limits of PAHs were between 0.11-1.40 ng kg-1. The coating showed satisfied reproducibility and repeatability (RSD <8.6%) with only 10 mL of 10% (v/v) acetone in water used as the extraction phase in an effort to be environmentally friendly. All of the results showed that the method is simple, sensitive, and robust. SPME Arrows with UiO-66/MoS2 coatings can provide new opportunities for the efficient extraction of persistent organic pollutants in food safety applications.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  GC–MS; MoS(2); Polycyclic aromatic hydrocarbons; Solid-phase microextraction Arrow; UiO-66

Mesh:

Substances:

Year:  2019        PMID: 30711322     DOI: 10.1016/j.chroma.2019.01.066

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

Review 1.  [Recent advances in sample preparation technologies for analysis of harmful substances in aquatic products].

Authors:  Xingyi Wang; Yanlong Chen; Xiaohua Xiao; Gongke Li
Journal:  Se Pu       Date:  2021-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.