Hemodynamic analysis of a novel stent graft design with slit perforations in thoracic aortic aneurysm.

ChiWei Ong1, Fei Xiong1, Foad Kabinejadian2, Gideon Praveen Kumar3, FangSen Cui3, Gongfa Chen4, Pei Ho5, HwaLiang Leo6.   

Abstract

Thoracic endovascular aortic repair (TEVAR) has been introduced as a less invasive approach to the treatment of thoracic aortic aneurysm (TAA). However, the effectiveness of TEVAR in the treatment of TAA is often limited due to the complex anatomy of aortic arch. Flow preservation at the three supra-aortic branches further increases the overall technical difficulty. This study proposes a novel stent graft design with slit perforations that can positively alter the hemodynamics at the aortic arch while maintaining blood flow to supra-aortic branches. We carried out a computational fluid dynamic (CFD) analysis to evaluate flow characteristics near stented aortic arch in simplified TAA models, followed by in-vitro experiments using particle image velocimetry (PIV) in a mock circulatory loop. The hemodynamics result was studied in terms of time-averaged wall shear stress (TAWSS), oscillating shear index (OSI), and endothelial cell action potential (ECAP). The results showed that the stent graft with slit perforations can reduce the disturbed flow region considerably. Furthermore, the effect of the slits on flow preservation to the supra-aortic branches was simulated and compared with experimental results. The effectiveness of the stent graft with slit perforations in preserving flow to the branches was demonstrated by both simulated and experimental results. Low TAWSS and elevated ECAP were observed in the aortic arch aneurysm after the placement of the stent graft with slits, implying the potential of thrombus formation in the aneurysm. On the other hand, the effects of the stent grafts with full-slit design and half-slit design on the shear stress did not differ significantly. The present analysis indicated that not only could the stent graft with slit perforations shield the aneurysm from rupture, but also it resulted in a favorable environment for thrombus that can contribute to the shrinkage of the aneurysm.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computational fluid dynamics; Flow preservation; Particle image velocimetry; Shear stress; Thoracic aortic aneurysm

Mesh:

Year:  2019        PMID: 30704763     DOI: 10.1016/j.jbiomech.2019.01.019

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Haemodynamic Analysis of Branched Endografts for Complex Aortic Arch Repair.

Authors:  Sampad Sengupta; Mohamad Hamady; Xiao-Yun Xu
Journal:  Bioengineering (Basel)       Date:  2022-01-18

2.  Hemodynamic numerical simulation of aortic arch modular inner branched stent-graft in eight early patients from the first-in-human case series.

Authors:  Yating Zhu; Fen Li; Hongpeng Zhang; Hui Song; Xiaodan Ma; Long Cao; Wenjun Zhang; Wei Guo
Journal:  Front Cardiovasc Med       Date:  2022-08-30

3.  On the Potential Self-Amplification of Aneurysms Due to Tissue Degradation and Blood Flow Revealed From FSI Simulations.

Authors:  Haifeng Wang; Daniel Balzani; Vijay Vedula; Klemens Uhlmann; Fathollah Varnik
Journal:  Front Physiol       Date:  2021-12-10       Impact factor: 4.566

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.