Literature DB >> 30698007

Spheroid-3D and Monolayer-2D Intestinal Electrochemical Biosensor for Toxicity/Viability Testing: Applications in Drug Screening, Food Safety, and Environmental Pollutant Analysis.

Evangelia Flampouri1, Shahzad Imar1, Kieran OConnell1,2, Baljit Singh1,2.   

Abstract

The rise of three-dimensional cell culture systems that provide in vivo-like environments for pharmaco-toxicological models has prompted the need for simple and robust viability assays suitable for complex cell architectural structures. This study addresses that challenge with the development of an in vitro enzyme based electrochemical sensor for viability/cytotoxicity assessment of two-dimensional (2D) monolayer and three-dimensional (3D) spheroid culture formats. The biosensor measures the cell viability/toxicity via electrochemical monitoring of the enzymatic activity of nonspecific esterases of viable cells, through the hydrolysis of 1-naphthyl acetate to 1-naphthol. The proposed sensor demonstrated strong correlation ( r = 0.979) with viable cell numbers. Furthermore, the model intestinal toxicants diclofenac (DFC, pharmaceutical), okadaic acid (OA, food-safety), and mancozeb (MZB, environmental) were used for the functional evaluation of the proposed sensor using 2D and 3D culture formats. Sensor performance showed high consistency with conventional cell viability/cytotoxicity assays (MTT/CFDA-AM) for all toxicants, with the sensor IC50 values matching the relevant viability LC50 values at the 95% confidence interval range for 2D (DCF: 1.19-1.26 mM, MZB: 10.28-14.18 μM, OA: 40.91-77.13 nM) and 3D culture formats (DCF: 1.02-4.78 mM, MZB: 11.26-15.16 μM, OA: 162.09-179.67 nM). The presented results demonstrate the feasibility of the proposed sensor as a robust endpoint screening tool for both 2D and 3D cytotoxicity assessment.

Entities:  

Keywords:  cytotoxicity; screen-printed electrode; spheroid-3D, electrochemical biosensor; substrate and enzymatic product; viability, nonspecific esterase

Mesh:

Substances:

Year:  2019        PMID: 30698007     DOI: 10.1021/acssensors.8b01490

Source DB:  PubMed          Journal:  ACS Sens        ISSN: 2379-3694            Impact factor:   7.711


  7 in total

Review 1.  Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19.

Authors:  Nikhil Bhalla; Yuwei Pan; Zhugen Yang; Amir Farokh Payam
Journal:  ACS Nano       Date:  2020-06-26       Impact factor: 15.881

2.  Phenolic water toxins: redox mechanism and method of their detection in water and wastewater.

Authors:  Tayyaba Kokab; Afzal Shah; Jan Nisar; Muhammad Naeem Ashiq; M Abdullah Khan; Sher Bahadar Khan; Esraa M Bakhsh
Journal:  RSC Adv       Date:  2021-11-05       Impact factor: 4.036

Review 3.  Application of electrochemical biosensors in tumor cell detection.

Authors:  Zhenhua Zhang; Qingchao Li; Xin Du; Min Liu
Journal:  Thorac Cancer       Date:  2020-02-26       Impact factor: 3.500

Review 4.  Recent Advances in Electrochemical Sensors for the Detection of Biomolecules and Whole Cells.

Authors:  Intan Rosalina Suhito; Kyeong-Mo Koo; Tae-Hyung Kim
Journal:  Biomedicines       Date:  2020-12-26

Review 5.  Three-Dimensional Spheroids as In Vitro Preclinical Models for Cancer Research.

Authors:  Bárbara Pinto; Ana C Henriques; Patrícia M A Silva; Hassan Bousbaa
Journal:  Pharmaceutics       Date:  2020-12-06       Impact factor: 6.321

6.  The utility of biomedical scaffolds laden with spheroids in various tissue engineering applications.

Authors:  SooJung Chae; Jiyoung Hong; Hanjun Hwangbo; GeunHyung Kim
Journal:  Theranostics       Date:  2021-05-03       Impact factor: 11.556

Review 7.  [Research advances of high-throughput cell-based drug screening systems based on microfluidic technique].

Authors:  Yixiao Liang; Jianzhang Pan; Qun Fang
Journal:  Se Pu       Date:  2021-06
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.