Calculation of dose volume parameters and indices in plan evaluation of HDR interstitial brachytherapy by MUPIT in carcinoma cervix.

Jyoti Poddar1, Ashutosh Das Sharma1, U Suryanarayan1, Sonal Patel Shah1, Ankita Parikh1, Vimesh Mehta1, Tarun Kumar1.   

Abstract

BACKGROUND: Evaluation of a HDR- interstitial brachytherapy plan is a challenging job. Owing to the complexities and diversity of the normalization and optimization techniques involved, a simple objective assessment of these plans is required. This can improve the radiation dose coverage of the tumour with decreased organ toxicity. AIM: To study and document the various dose volume indices and parameters required to evaluate a HDR interstitial brachytherapy plan by Volume normalization and graphical optimization using MUPIT (Martinez Universal Perineal Interstitial Template) in patients of carcinoma cervix. SETTINGS AND
DESIGN: Single arm, retrospective study. METHODS AND MATERIALS: 35 patients of carcinoma cervix who received EBRT and HDR brachytherapy using MUPIT, were selected. The dose prescribed was 4 Gray/Fraction in four fractions (16Gy/4) treated twice daily, at least 6 hours apart. CTV and OARs were delineated on the axial CT image set. Volume normalization and graphical optimization was done for planning. Coverage Index (CI), Dose homogeneity index (DHI), Overdose index (OI), Dose non-uniformity ratio (DNR), Conformity Index (COIN) and dose volume parameters i.e. D2cc, D1cc, D0.1cc of rectum and bladder were evaluated. STATISTICAL ANALYSIS: SPSS version 16 was used. RESULTS AND
CONCLUSION: CI was 0.95 ± 1.84 which means 95% of the target received 100% of the prescribed dose. The mean COIN was 0.841 ± 0.06 and DHI was 0.502 ± 0.11. D2cc rectum and bladder was 3.40 ± 0.56 and 2.95 ± 0.62 respectively which was within the tolerance limit of this organs. There should be an optimum balance between these indices for improving the quality of the implant and to yield maximum clinical benefit out of it, keeping the dose to the OARs in limit. Dose optimization should be carefully monitered and an institutional protocol should be devised for the acceptability criteria of these plans.

Entities:  

Keywords:  Cervical carcinoma; Martinez Universal Perineal Interstitial Template; dose volume indices; graphical optimization; interstitial brachytherapy; volume normalization

Mesh:

Year:  2018        PMID: 30693886     DOI: 10.4103/ijc.IJC_643_17

Source DB:  PubMed          Journal:  Indian J Cancer        ISSN: 0019-509X            Impact factor:   1.224


  2 in total

1.  Interstitial high-dose-rate brachytherapy using cobalt-60 source for cervical cancer: dosimetric and clinical outcomes from a single institute.

Authors:  Mohan Kumar; Revathy Thangaraj; Ram Charith Alva; Kirthi Koushik; Arul Ponni; Manur Gururajachar Janaki
Journal:  J Contemp Brachytherapy       Date:  2020-08-21

2.  Dosimetric comparison of manual forward planning with uniform dwell times versus volume-based inverse planning in interstitial brachytherapy of cervical malignancies.

Authors:  Siddanna R Palled; Nikhila K Radhakrishna; Senthil Manikantan; Hashmath Khanum; Bindu K Venugopal; Lokesh Vishwanath
Journal:  Rep Pract Oncol Radiother       Date:  2020-09-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.