Literature DB >> 30690848

Implant vs abutment level connection in implant supported screw-retained fixed partial dentures with cobalt-chrome framework: 1-year interim results of a randomized clinical study.

Marco Toia1, Michele Stocchero1, Jonas P Becktor1, Bruno Chrcanovic2, Ann Wennerberg3.   

Abstract

BACKGROUND: Screw-retained fixed partial dentures (FPD) have shown a lower incidence of biologic complications and an easier retrievability compared with cemented FPD.
PURPOSE: To compare the marginal bone loss at conical connection implant restored with a screw retained cobalt-chrome FPD in an implant-level (IL) or an abutment-level (AL) setup.
MATERIALS AND METHODS: Patients with at least two adjacent missing teeth were randomly allocated to be restored with IL or AL FPD. Periapical radiographs and clinical examination were taken at implant placement, prosthetic connection, 6 and 12 months to evaluate marginal bone loss (MBL), and soft tissue conditions. Complications were used to calculate prognostic indexes.
RESULTS: Fifty patients were treated with 50 FPD supported by 119 implants. The difference of MBL between the IL and AL groups was statistically significant (P = 0.003). At 1 year, MBL was 0.086 ± 0.313 mm and 0.005 ± 0.222 mm in the IL and AL groups, respectively. The presence of BoP increased with time in IL, whereas it decreased in AL group (P < 0.001). A minor complication was encounted in one FPD.
CONCLUSIONS: A low grade of MBL was present after 1 year. IL showed greater amount of MBL and soft tissue inflammation indexes than AL. In FPD, AL may be a safer procedure than IL setup in order to preserve a healthy periimplant tissue.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  Co-Cr; dental implant; fixed partial dentures; implant level connection; marginal bone loss

Mesh:

Substances:

Year:  2019        PMID: 30690848     DOI: 10.1111/cid.12717

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  1 in total

1.  Human Stem Cell Responses and Surface Characteristics of 3D Printing Co-Cr Dental Material.

Authors:  Boldbayar Ganbold; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Jaejin Cho
Journal:  Materials (Basel)       Date:  2019-10-18       Impact factor: 3.623