Reduction of Operator Hand Exposure in Interventional Radiology With a Novel Finger Sack Using Tungsten-containing Rubber.

Hiroyuki Kosaka1, Hajime Monzen1, Kenji Matsumoto1, Mikoto Tamura1, Yasumasa Nishimura2.   

Abstract

The purpose of this study was to evaluate the x-ray shielding ability of a novel tungsten-particle-containing rubber-based finger sack for use in interventional radiology. Shielding rates for the air kerma (mGy m) were measured using a semiconductor dosimeter with and without the finger sack and commercial lead gloves, at a 20 cm distance from the field of view. A C-arm digital angiography system was used with x-ray tube voltages of 60, 80, 100, and 120 kVp. In addition, the 70 μm dose equivalent to the operator's finger was measured using fluorescent glass dosimeters with and without the finger sack during interventional radiology examinations. The x-ray shielding rates for 60, 80, 100, and 120 kV x rays were 98.0 ± 0.03%, 94.8 ± 0.05%, 92.3 ± 0.12%, and 90.1 ± 0.03%, respectively, with the finger sack and 69.8 ± 0.39%, 61.0 ± 0.53%, 52.3 ± 0.52%, and 47.0 ± 0.69% with the lead gloves. The x-ray shielding rates for the fluoroscopy and cine mode with the finger sack were 91.3 ± 0.21% and 56.5 ± 0.58%, respectively, while with the lead gloves they were 96.5 ± 0.04% and 67.6 ± 0.33%. The 70 μm dose equivalent for the operator's finger exposure dose was reduced by approximately 39.4% using the finger sack. The finger shields were more user friendly, had excellent radiation shielding ability against x rays, and should reduce finger exposure in interventional radiology.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30688684     DOI: 10.1097/HP.0000000000000992

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  2 in total

1.  Dosimetric evaluation of skin collimation with tungsten rubber for electron radiotherapy: A Monte Carlo study.

Authors:  Kazuki Wakabayashi; Hajime Monzen; Mikoto Tamura; Kenji Matsumoto; Yoshiki Takei; Yasumasa Nishimura
Journal:  J Appl Clin Med Phys       Date:  2021-02-26       Impact factor: 2.102

2.  Estimating radiation exposure of the brain of a physician with a protective flap in interventional radiology: A phantom study.

Authors:  Shota Hattori; Hajime Monzen; Mikoto Tamura; Hiroyuki Kosaka; Yasunori Nakamura; Yasumasa Nishimura
Journal:  J Appl Clin Med Phys       Date:  2022-01-19       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.