Effects of a contingent vibratory stimulus delivered by an intra-oral device on sleep bruxism: a pilot study.

Hirotaka Nakamura1, Masayuki Takaba1, Yuka Abe1, Shuichiro Yoshizawa1, Takeshi Suganuma2, Yuya Yoshida1, Yukari Nakazato1, Yasuhiro Ono1, Glenn T Clark3, Kazuyoshi Baba4.   

Abstract

PURPOSE: Although sleep bruxism (SB) is one of the most important clinical problems in dental practice, there is no definitive method for controlling it. This pilot study evaluated the effects of contingent vibratory feedback stimuli using an occlusal splint for inhibition of sleep bruxism.
METHODS: Thirteen subjects with clinically diagnosed SB participated after providing an informed consent. Portable polysomnographic recordings were conducted in the subjects' home environment to make a definitive SB diagnosis and to evaluate the effects of the vibratory stimuli on SB. A force-based bruxism detection system, which used a pressure-sensitive piezoelectric film embedded in the occlusal splint, was utilized to trigger vibration feedback stimuli, which was scheduled to be applied intermittently for 30 min, at 30-min intervals.
RESULTS: The number of SB episodes (times/hour), the total SB duration (seconds/hour), the mean duration of SB episodes (seconds/episode), and the micro-arousal index (times/hour) were scored for each time period (with and without vibration). The effects of the vibration on these scores were tested (paired t test; p < 0.05). The number of SB episodes tended to decrease with the vibration stimuli, and the decrease in the total SB duration was statistically significant (14.3 ± 9.5 vs. 26.0 ± 20.0, p = 0.03). No substantial change was found in terms of the micro-arousal index.
CONCLUSIONS: These study results suggested that the SB inhibitory system employing a vibratory stimulus might be able to suppress the total SB duration without disturbing sleep.

Entities:  

Keywords:  Biofeedback; Masseter EMG activity; Portable polysomnography; Sleep bruxism; Stabilization splint

Mesh:

Year:  2019        PMID: 30685853     DOI: 10.1007/s11325-019-01782-x

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  4 in total

1.  Customized Appliance Device for Force Detection in Bruxism Individuals: An Observational Study.

Authors:  Matteo Pollis; Pietro Maoddi; Marco Letizia; Daniele Manfredini
Journal:  Int J Dent       Date:  2022-06-14

2.  Effects of vibratory feedback stimuli through an oral appliance on sleep bruxism: a 6-week intervention trial.

Authors:  Hironobu Ohara; Masayuki Takaba; Yuka Abe; Yukari Nakazato; Risa Aoki; Yuya Yoshida; Takeshi Suganuma; Kazuyoshi Baba
Journal:  Sleep Breath       Date:  2021-08-09       Impact factor: 2.816

3.  Intelligent Occlusion Stabilization Splint with Stress-Sensor System for Bruxism Diagnosis and Treatment.

Authors:  Jinxia Gao; Longjun Liu; Peng Gao; Yihuan Zheng; Wenxuan Hou; Junhui Wang
Journal:  Sensors (Basel)       Date:  2019-12-22       Impact factor: 3.576

Review 4.  Managements of sleep bruxism in adult: A systematic review.

Authors:  Hajime Minakuchi; Masanori Fujisawa; Yuka Abe; Takashi Iida; Kyosuke Oki; Kazuo Okura; Norimasa Tanabe; Akira Nishiyama
Journal:  Jpn Dent Sci Rev       Date:  2022-03-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.