A novel microfluidic resistive pulse sensor with multiple voltage input channels and a side sensing gate for particle and cell detection.

Tong Zhou1, Yongxin Song1, Yapeng Yuan1, Dongqing Li2.   

Abstract

Traditionally, a resistive pulse sensor (also known as Coulter counter) works by letting a particle pass through a small orifice in an electrolyte solution. The detection sensitivity mainly relies on the volume ratio of the particle to the orifice. This paper presents a novel resistive pulse sensor which has a sensing orifice located on the side wall of a microchannel. In this way, the sensor can detect and count particles (or cells) without requiring particles (or cells) passing through the sensing gate. An equation was derived to relate the magnitudes of the detected signals and the electrical resistances. Results show that the magnitudes of the detected signals can be increased by applying voltages from more than one voltage input channels simultaneously. Under the same conditions, the magnitudes of the detected signals become larger when the diameters of particles are larger. Higher detection sensitivity can be obtained simply by increasing either the magnitudes of the applied voltages or the number of the voltage input channels, or reducing the opening of the side sensing gate to a size that is even smaller than the diameter of the particle. Due to the high detection sensitivity, detection of 1 μm particles by a relatively large sensing gate of 5 × 10 × 10 μm (width × length × height) was successfully demonstrated with a signal to noise ratio (S/N) of approximately 3. This sensor was also applied to detect and count human red blood cells and lymphocyte cells. Results show that this method can clearly distinguish the cells with different sizes based on the pre-determined-thresholds. Because this sensor does not require cells to pass through the sensing gate, the channel clogging problem can be avoided. More importantly, the detection sensitivity can be tuned by applying different voltages without fabricating a smaller sensing gate.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cell detection; Multiple voltage input channels; Resistive pulse sensing; Side sensing gate

Mesh:

Year:  2018        PMID: 30685029     DOI: 10.1016/j.aca.2018.11.049

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

Review 1.  Recent Advances in Continuous-Flow Particle Manipulations Using Magnetic Fluids.

Authors:  Xiangchun Xuan
Journal:  Micromachines (Basel)       Date:  2019-10-31       Impact factor: 2.891

Review 2.  Microfluidic devices for the detection of viruses: aspects of emergency fabrication during the COVID-19 pandemic and other outbreaks.

Authors:  José Alvim Berkenbrock; Rafaela Grecco-Machado; Sven Achenbach
Journal:  Proc Math Phys Eng Sci       Date:  2020-11-04       Impact factor: 2.704

3.  Simultaneous and continuous particle separation and counting via localized DC-dielectrophoresis in a microfluidic chip.

Authors:  Yongxin Song; Xiaoshi Han; Deyu Li; Qinxin Liu; Dongqing Li
Journal:  RSC Adv       Date:  2021-01-19       Impact factor: 3.361

4.  Study of the Pattern Preparation and Performance of the Resistance Grid of Thin-Film Strain Sensors.

Authors:  Yunping Cheng; Wenge Wu; Yongjuan Zhao; Yanwen Han; Ding Song
Journal:  Micromachines (Basel)       Date:  2022-06-01       Impact factor: 3.523

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.