Literature DB >> 30680555

Rapid antibiotic susceptibility testing in blood culture diagnostics performed by direct inoculation using the VITEK®-2 and BD Phoenix™ platforms.

Steffen Höring1, Alain Sami Massarani2, Bettina Löffler2, Jürgen Rödel2.   

Abstract

Early availability of microbiological results can improve treatment decisions of patients suffering from bloodstream infections. Direct inoculation of automated susceptibility testing (AST) platforms is an approach to shorten time-to-result in blood culture diagnostics. We performed a comparative evaluation of the two commercial AST systems VITEK®-2 and BD Phoenix™ for the direct inoculation with blood culture samples. Furthermore, two different methods of sample preparation were compared in this study. Positive blood cultures were prepared for direct inoculation by use of serum separator tubes and twofold centrifugation. AST was performed with the VITEK®-2 and the BD Phoenix™ system by the standard method according to the manufacturer's recommendations using subcultures on solid media and by direct inoculation of blood culture samples. A hundred clinical samples from blood cultures were included in this study. Rapid AST by direct inoculation showed inter-test agreement rates ranging from 92.45 to 97.7%. Comparing both AST platforms, the VITEK®-2 system demonstrated a higher test accuracy for direct inoculation. No relevant difference was observed for the two different sample preparation methods. Direct inoculation is an easy and inexpensive approach to obtain early full panel phenotypic AST results in blood culture diagnostics. Sample preparation is sufficiently performed by a simple centrifugation method. Both commercial platforms, the VITEK®-2 and the BD Phoenix™, have proven suitable for the use of direct inoculation.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30680555     DOI: 10.1007/s10096-018-03445-3

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  4 in total

1.  Evaluation of the Performance of Direct Susceptibility Test by VITEK-2 from Positively Flagged Blood Culture Broth for Gram-Negative Bacilli.

Authors:  D Kavipriya; Suman Susan Prakash; Sarumathi Dhandapani; Deepashree Rajshekar; Apurba Sankar Sastry
Journal:  J Lab Physicians       Date:  2021-07-09

2.  Comparison of novel rapid diagnostic of blood culture identification and antimicrobial susceptibility testing by Accelerate Pheno system and BioFire FilmArray Blood Culture Identification and BioFire FilmArray Blood Culture Identification 2 panels.

Authors:  Dorothy T T Sze; Candy C Y Lau; Tsz-Ming Chan; Edmond S K Ma; Bone S F Tang
Journal:  BMC Microbiol       Date:  2021-12-18       Impact factor: 3.605

3.  Impact of a Laboratory-Developed Phenotypic Rapid Susceptibility Test Directly From Positive Blood Cultures on Time to Narrowest Effective Therapy in Patients With Gram-Negative Bacteremia: A Prospective Randomized Trial.

Authors:  Alyssa B Christensen; Brent Footer; Tobias Pusch; Kim Heath; Maha Iqbal; Lian Wang; Gregory Tallman; Cameron Cover; Jennifer Marfori; Brian Kendall; Nick Stucky; Meagan Greckel; Ivor L Thomas; Katelynn Tran; Salena Yip; Margret Oethinger
Journal:  Open Forum Infect Dis       Date:  2022-07-22       Impact factor: 4.423

Review 4.  Modern Blood Culture: Management Decisions and Method Options.

Authors:  Mark D Gonzalez; Timothy Chao; Matthew A Pettengill
Journal:  Clin Lab Med       Date:  2020-09-19       Impact factor: 1.935

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.