Literature DB >> 30680425

A simple, fast method for the analysis of 20 contaminants of emerging concern in river water using large-volume direct injection liquid chromatography-tandem mass spectrometry.

Josep Borrull1,2, Agustí Colom1, Josepa Fabregas1, Eva Pocurull3, Francesc Borrull2.   

Abstract

A fast and sensitive method for the determination of a structurally and physico-chemically diverse group of contaminants of emerging concern (CEC) based on large-volume direct injection liquid chromatography-tandem mass spectrometry was developed. The method can be used to determine 20 CECs belonging to different pollutant families (pharmaceuticals, personal care products, and pesticides) in river water at nanogram per liter. A single analytical run is required and the positive and negative ionization modes can be used simultaneously. Because of the large-volume injections of samples and the high sensitivity of the current mass spectrometers, the method has no need of a preconcentration step. The analytes are quantitated with matrix-matched calibration curves. The estimated limits of detection were in the range 0.1-5 ng L-1. The accuracy of the method was in the range 86-114%, and the precision, expressed as a relative standard deviation (RSD %), was below 18% for all the analytes (n = 5, at 5, 10, and 25 ng L-1). The method was applied to water samples taken from different points along the lower course of the Ebro River, Spain. A total of 12 out of the 20 target analytes were detected, and the ones at higher concentrations were caffeine and the pharmaceuticals paracetamol and ibuprofen (184.8 ng L-1, 63.3 ng L-1, and 23.3 ng L-1, respectively).

Entities:  

Keywords:  Direct large-volume injection; Liquid chromatography; Multi-residue analysis; Surface water; Tandem mass spectrometry

Year:  2019        PMID: 30680425     DOI: 10.1007/s00216-019-01602-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Electrode modified with graphene quantum dots supported in chitosan for electrochemical methods and non-linear deconvolution of spectra for spectrometric methods: approaches for simultaneous determination of triclosan and methylparaben.

Authors:  Edson Roberto Santana; Almir Spinelli
Journal:  Mikrochim Acta       Date:  2020-03-28       Impact factor: 5.833

2.  Quantitative Determination and Environmental Risk Assessment of 102 Chemicals of Emerging Concern in Wastewater-Impacted Rivers Using Rapid Direct-Injection Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Melanie Egli; Alicia Hartmann; Helena Rapp Wright; Keng Tiong Ng; Frédéric B Piel; Leon P Barron
Journal:  Molecules       Date:  2021-09-07       Impact factor: 4.927

3.  Non-targeted analysis with high-resolution mass spectrometry for investigation of riverbank filtration processes.

Authors:  Kaan Georg Kutlucinar; Sebastian Handl; Roza Allabashi; Tim Causon; Christina Troyer; Ernest Mayr; Reinhard Perfler; Stephan Hann
Journal:  Environ Sci Pollut Res Int       Date:  2022-04-26       Impact factor: 5.190

4.  High-throughput multi-residue quantification of contaminants of emerging concern in wastewaters enabled using direct injection liquid chromatography-tandem mass spectrometry.

Authors:  Keng Tiong Ng; Helena Rapp-Wright; Melanie Egli; Alicia Hartmann; Joshua C Steele; Juan Eduardo Sosa-Hernández; Elda M Melchor-Martínez; Matthew Jacobs; Blánaid White; Fiona Regan; Roberto Parra-Saldivar; Lewis Couchman; Rolf U Halden; Leon P Barron
Journal:  J Hazard Mater       Date:  2020-05-24       Impact factor: 10.588

5.  An Alternative Strategy for Screening and Confirmation of 330 Pesticides in Ground- and Surface Water Using Liquid Chromatography Tandem Mass Spectrometry.

Authors:  Edgár Tóth; Ádám Tölgyesi; Andrea Simon; Mária Bálint; Xingmao Ma; Virender K Sharma
Journal:  Molecules       Date:  2022-03-14       Impact factor: 4.411

  5 in total