Literature DB >> 30677165

Malaligned bioprosthetic valve causing left ventricular outflow tract obstruction.

Panagiota Christia1, Samantha Lee1, Olha Lyuba1, Jeffrey J Silbiger1.   

Abstract

Left ventricular outflow tract obstruction resulting from strut impingement upon the interventricular septum is a rare complication of bioprosthetic mitral valve insertion. Obstruction is more likely to develop when a small, high profile prosthetic valve is inserted into a patient with a small outflow tract. The likelihood of this complication may be reduced by appropriate modification of surgical technique.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  aorto-mitral angle; bioprosthetic valve; left ventricular outflow tract obstruction; mitral valve replacement

Mesh:

Year:  2019        PMID: 30677165     DOI: 10.1111/echo.14255

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  1 in total

1.  3-dimensional printing for the diagnosis of left ventricular outflow tract obstruction after mitral valve replacement.

Authors:  Ralf Sodian; Michael Kruttschnitt; Niklas Hitschrich; Bernhard Mumm; Christian Schnell; Christian Hagl; Nikolaus Thierfelder; Fabian König
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10
  1 in total