Literature DB >> 30677164

Influence of stems and metaphyseal sleeve on primary stability of cementless revision tibial trays used to reconstruct AORI IIB defects.

Maged Awadalla1, Rami M A Al-Dirini1, Dermot O'Rourke1, Lucian B Solomon2,3, Mark Heldreth4, Paul Rullkoetter5, Mark Taylor1.   

Abstract

Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone. Finite element models were generated from computed tomography (CT) scans of nine individuals. All the bones used in the study had an AORI type IIB defect. The cohort included eight females (mean weight: 64 kg, height: 1.6 m). Material properties were sampled from CT data and assigned to the FE model. Joint contact forces for level gait, stair descent, and squat were applied. Stemless sleeved implants under various loading conditions were shown to have adequate primary stability in all AORI type IIB defects investigated. Adding a stem only marginally improved the primary stability of the implant but reduced the strain in the metaphysis compared to stemless implants. Once good initial mechanical stability was established with a sleeve, there was no benefit, in terms of primary stability or bone strains, from increasing sleeve size. This study suggests that metaphyseal sleeves, without a stem, can provide the required primary stability required by a rTKR tibial implant, to reconstruct an AORI type IIB defect.
© 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  AORI-IIB; FEA; Tibia; metaphyseal-sleeve; revision

Year:  2019        PMID: 30677164     DOI: 10.1002/jor.24232

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

Review 1.  Bone defect classifications in revision total knee arthroplasty, their reliability and utility: a systematic review.

Authors:  Yasim Khan; Sumit Arora; Abhishek Kashyap; Mohit Kumar Patralekh; Lalit Maini
Journal:  Arch Orthop Trauma Surg       Date:  2022-07-03       Impact factor: 3.067

2.  Is stemless implant fixation a valid option in total knee revision arthroplasty - Review of in vitro and in vivo studies.

Authors:  H Graichen; W Scior
Journal:  J Orthop       Date:  2021-01-05

3.  Metaphyseal cones in revision total knee arthroplasty: The role of stems.

Authors:  Shuqiao Xie; Noel Conlisk; David Hamilton; Chloe Scott; Richard Burnett; Pankaj Pankaj
Journal:  Bone Joint Res       Date:  2020-05-16       Impact factor: 5.853

4.  A constrained-condylar fixed-bearing total knee arthroplasty is stabilised by the medial soft tissues.

Authors:  Kiron K Athwal; Lukas Willinger; William Manning; David Deehan; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-22       Impact factor: 4.342

  4 in total