Literature DB >> 30676953

Multi-Site Harmonization of Diffusion MRI Data via Method of Moments.

Khoi Minh Huynh, Geng Chen, Ye Wu, Dinggang Shen, Pew-Thian Yap.   

Abstract

Diffusion MRI is a powerful tool for non-invasive probing of brain tissue microstructure. Recent multi-center efforts in the acquisition and analysis of diffusion MRI data significantly increase sample sizes and hence improve sensitivity and reliability in detecting subtle changes associated with development, aging, and diseases. However, discrepancies resulting from different scanner vendors, acquisition protocols, and image reconstruction algorithms can cause data incompatibility across imaging centers. In this paper, we introduce a model-free method that is based on the method of moments for the direct harmonization of diffusion MRI data to reduce site-specific variations. Our method directly harmonizes diffusion-attenuated signal without the need to fit any diffusion model. Moreover, our method allows the explicit definition of well-behaved mapping functions with properties such as invertibility, smoothness, and injectivity. We show that our method is effective in lowering the variations of diffusion scalars of traveling human phantoms scanned at different sites from 1%-3% to less than 0.9% for fractional anisotropy (FA) and mean diffusivity and from 1%-2.5% to 0.3%-1.2% for generalized FA. We also demonstrate its ability in preserving individual differences and in increasing across-site consistency in tractography and white matter connectivity.

Entities:  

Mesh:

Year:  2019        PMID: 30676953      PMCID: PMC6606391          DOI: 10.1109/TMI.2019.2895020

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  29 in total

1.  The sva package for removing batch effects and other unwanted variation in high-throughput experiments.

Authors:  Jeffrey T Leek; W Evan Johnson; Hilary S Parker; Andrew E Jaffe; John D Storey
Journal:  Bioinformatics       Date:  2012-01-17       Impact factor: 6.937

2.  Harmonizing DTI measurements across scanners to examine the development of white matter microstructure in 803 adolescents of the NCANDA study.

Authors:  Kilian M Pohl; Edith V Sullivan; Torsten Rohlfing; Weiwei Chu; Dongjin Kwon; B Nolan Nichols; Yong Zhang; Sandra A Brown; Susan F Tapert; Kevin Cummins; Wesley K Thompson; Ty Brumback; Ian M Colrain; Fiona C Baker; Devin Prouty; Michael D De Bellis; James T Voyvodic; Duncan B Clark; Claudiu Schirda; Bonnie J Nagel; Adolf Pfefferbaum
Journal:  Neuroimage       Date:  2016-02-10       Impact factor: 6.556

3.  An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest.

Authors:  Rahul S Desikan; Florent Ségonne; Bruce Fischl; Brian T Quinn; Bradford C Dickerson; Deborah Blacker; Randy L Buckner; Anders M Dale; R Paul Maguire; Bradley T Hyman; Marilyn S Albert; Ronald J Killiany
Journal:  Neuroimage       Date:  2006-03-10       Impact factor: 6.556

4.  Tight Graph Framelets for Sparse Diffusion MRI q-Space Representation.

Authors:  Pew-Thian Yap; Bin Dong; Yong Zhang; Dinggang Shen
Journal:  Med Image Comput Comput Assist Interv       Date:  2016-10-02

5.  Harmonization of multi-site diffusion tensor imaging data.

Authors:  Jean-Philippe Fortin; Drew Parker; Birkan Tunç; Takanori Watanabe; Mark A Elliott; Kosha Ruparel; David R Roalf; Theodore D Satterthwaite; Ruben C Gur; Raquel E Gur; Robert T Schultz; Ragini Verma; Russell T Shinohara
Journal:  Neuroimage       Date:  2017-08-18       Impact factor: 6.556

Review 6.  The UNC/UMN Baby Connectome Project (BCP): An overview of the study design and protocol development.

Authors:  Brittany R Howell; Martin A Styner; Wei Gao; Pew-Thian Yap; Li Wang; Kristine Baluyot; Essa Yacoub; Geng Chen; Taylor Potts; Andrew Salzwedel; Gang Li; John H Gilmore; Joseph Piven; J Keith Smith; Dinggang Shen; Kamil Ugurbil; Hongtu Zhu; Weili Lin; Jed T Elison
Journal:  Neuroimage       Date:  2018-03-22       Impact factor: 6.556

7.  Multi-site harmonization of diffusion MRI data in a registration framework.

Authors:  Hengameh Mirzaalian; Lipeng Ning; Peter Savadjiev; Ofer Pasternak; Sylvain Bouix; Oleg Michailovich; Sarina Karmacharya; Gerald Grant; Christine E Marx; Rajendra A Morey; Laura A Flashman; Mark S George; Thomas W McAllister; Norberto Andaluz; Lori Shutter; Raul Coimbra; Ross D Zafonte; Mike J Coleman; Marek Kubicki; Carl-Fredrik Westin; Murray B Stein; Martha E Shenton; Yogesh Rathi
Journal:  Brain Imaging Behav       Date:  2018-02       Impact factor: 3.978

8.  Inter-site and inter-scanner diffusion MRI data harmonization.

Authors:  H Mirzaalian; L Ning; P Savadjiev; O Pasternak; S Bouix; O Michailovich; G Grant; C E Marx; R A Morey; L A Flashman; M S George; T W McAllister; N Andaluz; L Shutter; R Coimbra; R D Zafonte; M J Coleman; M Kubicki; C F Westin; M B Stein; M E Shenton; Y Rathi
Journal:  Neuroimage       Date:  2016-04-30       Impact factor: 6.556

Review 9.  The WU-Minn Human Connectome Project: an overview.

Authors:  David C Van Essen; Stephen M Smith; Deanna M Barch; Timothy E J Behrens; Essa Yacoub; Kamil Ugurbil
Journal:  Neuroimage       Date:  2013-05-16       Impact factor: 6.556

10.  Estimating and accounting for the effect of MRI scanner changes on longitudinal whole-brain volume change measurements.

Authors:  Hyunwoo Lee; Kunio Nakamura; Sridar Narayanan; Robert A Brown; Douglas L Arnold
Journal:  Neuroimage       Date:  2018-09-22       Impact factor: 6.556

View more
  7 in total

1.  Harmonization of Infant Cortical Thickness Using Surface-to-Surface Cycle-Consistent Adversarial Networks.

Authors:  Fenqiang Zhao; Zhengwang Wu; Li Wang; Weili Lin; Shunren Xia; Dinggang Shen; Gang Li
Journal:  Med Image Comput Comput Assist Interv       Date:  2019-10-10

2.  Data harmonisation for information fusion in digital healthcare: A state-of-the-art systematic review, meta-analysis and future research directions.

Authors:  Yang Nan; Javier Del Ser; Simon Walsh; Carola Schönlieb; Michael Roberts; Ian Selby; Kit Howard; John Owen; Jon Neville; Julien Guiot; Benoit Ernst; Ana Pastor; Angel Alberich-Bayarri; Marion I Menzel; Sean Walsh; Wim Vos; Nina Flerin; Jean-Paul Charbonnier; Eva van Rikxoort; Avishek Chatterjee; Henry Woodruff; Philippe Lambin; Leonor Cerdá-Alberich; Luis Martí-Bonmatí; Francisco Herrera; Guang Yang
Journal:  Inf Fusion       Date:  2022-06       Impact factor: 17.564

Review 3.  Harmonization of Brain Diffusion MRI: Concepts and Methods.

Authors:  Maíra Siqueira Pinto; Roberto Paolella; Thibo Billiet; Pieter Van Dyck; Pieter-Jan Guns; Ben Jeurissen; Annemie Ribbens; Arnold J den Dekker; Jan Sijbers
Journal:  Front Neurosci       Date:  2020-05-06       Impact factor: 4.677

4.  Deep learning-based unlearning of dataset bias for MRI harmonisation and confound removal.

Authors:  Nicola K Dinsdale; Mark Jenkinson; Ana I L Namburete
Journal:  Neuroimage       Date:  2020-12-30       Impact factor: 6.556

5.  Multi-Stage Harmonization for Robust AI across Breast MR Databases.

Authors:  Heather M Whitney; Hui Li; Yu Ji; Peifang Liu; Maryellen L Giger
Journal:  Cancers (Basel)       Date:  2021-09-26       Impact factor: 6.639

Review 6.  The sensitivity of diffusion MRI to microstructural properties and experimental factors.

Authors:  Maryam Afzali; Tomasz Pieciak; Sharlene Newman; Eleftherios Garyfallidis; Evren Özarslan; Hu Cheng; Derek K Jones
Journal:  J Neurosci Methods       Date:  2020-10-02       Impact factor: 2.390

Review 7.  Variability and Standardization of Quantitative Imaging: Monoparametric to Multiparametric Quantification, Radiomics, and Artificial Intelligence.

Authors:  Akifumi Hagiwara; Shohei Fujita; Yoshiharu Ohno; Shigeki Aoki
Journal:  Invest Radiol       Date:  2020-09       Impact factor: 10.065

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.