Deep-ultraviolet laser ablation electrospray ionization mass spectrometry.

Remilekun O Lawal1, Fabrizio Donnarumma1, Kermit K Murray1.   

Abstract

A 193-nm wavelength deep ultraviolet laser was used for ambient laser ablation electrospray ionization mass spectrometry of biological samples. A pulsed ArF excimer laser was used to ablate solid samples, and the resulting plume of the desorbed material merged with charged electrospray droplets to form ions that were detected with a quadrupole time-of-flight mass spectrometer. Solutions containing peptide and protein standards up to 66-kDa molecular weight were deposited on a metal target, dried, and analyzed. No fragmentation was observed from peptides and proteins as well as from the more easily fragmented vitamin B12 molecule. The mass spectra contained peaks from multiply charged ions that were identical to conventional electrospray. Deep UV laser ablation of tissue allowed detection of lipids from untreated tissue. The mechanism of ionization is postulated to involve absorption of laser energy by a fraction of the analyte molecules that act as a sacrificial matrix or by residual water in the sample.
© 2019 John Wiley & Sons, Ltd.

Entities:  

Keywords:  ambient; electrospray; excimer; laser ablation; ultraviolet

Year:  2019        PMID: 30675964      PMCID: PMC6422691          DOI: 10.1002/jms.4338

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  44 in total

1.  Collision-induced dissociation of ions within the orifice-skimmer region of an electrospray mass spectrometer

Authors: 
Journal:  Anal Chem       Date:  2000-02-15       Impact factor: 6.986

2.  Atmospheric pressure laser desorption/chemical ionization mass spectrometry: a new ionization method based on existing themes.

Authors:  Joshua J Coon; Kevin J McHale; W W Harrison
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

3.  Desorption/ionization of biomolecules from aqueous solutions at atmospheric pressure using an infrared laser at 3 microm.

Authors:  Victor V Laiko; Nelli I Taranenko; Vadym D Berkout; Mikhail A Yakshin; Coorg R Prasad; H Sang Lee; Vladimir M Doroshenko
Journal:  J Am Soc Mass Spectrom       Date:  2002-04       Impact factor: 3.109

Review 4.  Mechanisms of pulsed laser ablation of biological tissues.

Authors:  Alfred Vogel; Vasan Venugopalan
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

5.  Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  V V Laiko; M A Baldwin; A L Burlingame
Journal:  Anal Chem       Date:  2000-02-15       Impact factor: 6.986

6.  Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids.

Authors:  Jentaie Shiea; Min-Zon Huang; Hsiu-Jung Hsu; Chi-Yang Lee; Cheng-Hui Yuan; Iwona Beech; Jan Sunner
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

7.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

8.  Measurement of small-signal absorption coefficient and absorption cross section of collagen for 193-nm excimer laser light and the role of collagen in tissue ablation.

Authors:  Brian T Fisher; David W Hahn
Journal:  Appl Opt       Date:  2004-10-10       Impact factor: 1.980

9.  In situ structural characterization of phosphatidylcholines in brain tissue using MALDI-MS/MS.

Authors:  Shelley N Jackson; Hay-Yan J Wang; Amina S Woods
Journal:  J Am Soc Mass Spectrom       Date:  2005-10-25       Impact factor: 3.109

10.  Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

Authors:  Zoltán Takáts; Justin M Wiseman; Bogdan Gologan; R Graham Cooks
Journal:  Science       Date:  2004-10-15       Impact factor: 47.728

View more