Literature DB >> 30675655

Stereotactic brain biopsy: evaluation of robot-assisted procedure in 60 patients.

Laura Terrier1, Vianney Gilard2, Florent Marguet3, Maxime Fontanilles4, Stéphane Derrey2,5.   

Abstract

BACKGROUND: Frameless stereotactic biopsies, particularly robot-assisted procedures are increasing in neurosurgery centers. Results of these procedures should be at least equal to or greater than frame-based reference procedure. Evaluate robot-assisted technology is necessary in particular, when a team has chosen to switch from one to another method.
OBJECTIVE: The objective of our prospective work was (i) to evaluate the success rate of contributive robotic-assisted biopsy in 60 patients, to report the morbidity and mortality associated with the procedure and (ii) to compare it with literature data.
METHODS: We performed a prospective and descriptive study including 60 consecutive patients having had robotic-assisted stereotactic biopsy at the Rouen University Hospital, France. All patients had presurgical imaging before the procedure included Magnetic Resonance Imaging merged with Computed Tomography scan acquisition. Registration was mostly performed with a touch-free laser (57/60). A control Computed Tomography scan was always realized at day 0 or day 1 after surgery. Data collected were success rate, bleeding, clinical worsening, infection, and mortality.
RESULTS: All the biopsies were considered as contributive and lead to the final diagnosis. In 41/60 patients (68%), the lesion was glial. Six in 60 patients (10%) had visible bleeding without clinical worsening related, 5/60 patients (8.5%) showed clinical impairment following surgery, which was permanent in 2 patients, and 1/60 patient presented generalized seizures. We did not report any infection and mortality.
CONCLUSION: Robot-assisted frameless surgery is efficient and provides a reasonable alternative to frame-based procedure. The operating time can be reduced, without increasing morbidity and mortality rates.

Entities:  

Keywords:  Biopsy; Brain; Oncology; Robot assisted; Stereotactic

Year:  2019        PMID: 30675655     DOI: 10.1007/s00701-019-03808-5

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  2 in total

1.  Stealth Autoguide for robotic-assisted laser ablation for lesional epilepsy: illustrative case.

Authors:  David J Mazur-Hart; Nasser K Yaghi; Maryam N Shahin; Ahmed M Raslan
Journal:  J Neurosurg Case Lessons       Date:  2022-02-07

2.  A comparative study on the efficacy of robot of stereotactic assistant and frame-assisted stereotactic drilling, drainage for intracerebral hematoma in patients with hypertensive intracerebral hemorrhage.

Authors:  Liang Liang; Xin Li; Haiqing Dong; Xin Gong; Guanpeng Wang
Journal:  Pak J Med Sci       Date:  2022 Sep-Oct       Impact factor: 2.340

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.