Literature DB >> 30666851

Novel ractopamine-protein carrier conjugation and its application to the lateral flow strip test for ractopamine detection in animal feed.

Pattarachaya Preechakasedkit1, Nattaya Ngamrojanavanich2,3, Nanthika Khongchareonporn3, Orawon Chailapakul2,4.   

Abstract

In this work, a novel conjugate of ractopamine and bovine serum albumin (RAC-BSA) has been developed via the Mannich reaction, with a mole coupling ratio for RAC-BSA of 9:1. The proposed conjugation method provides a simple and one-step method with the use of fewer reagents compared with other conjugation methods for competitive immunoassays. RAC-BSA conjugation was used to fabricate a competitive lateral flow strip test for RAC detection in animal feed. For sample preparation, RAC was spiked in swine feed purchased from the local markets in Thailand, and methanol and running buffer at a volume ratio of 10:90 was used as extraction buffer. The procedures for sample preparation were completed within 25 min. Under optimal conditions, the limit of detection (LOD), assessed by the naked eye within 5 min, was found to be 1 ng/g. A semi-quantitative analysis was also conducted using a smart phone and computer software, with a linearity of 0.075-0.750 ng/g, calculated LOD of 0.10 ng/g, calculated limit of quantitation of 0.33 ng/g, and good correlation of 0.992. The recoveries were found in the range of 96.4%-103.7% with a relative standard deviation of 2.5%-3.6% for intra- and inter-assays. Comparison of the results obtained by the strip test with those obtained by enzyme-linked immunosorbent assay had a good agreement in terms of accuracy. Furthermore, this strip test exhibited highly specific RAC detection without cross reactivity with related compounds. Therefore, the RAC-BSA conjugation via the Mannich reaction can be accepted as a one-step and easy conjugation method and applied to the competitive lateral flow strip test.

Entities:  

Keywords:  Ractopamine; Conjugate of ractopamine and bovine serum albumin (RAC–BSA); Mannich reaction; Lateral flow strip test; Feed additive

Mesh:

Substances:

Year:  2019        PMID: 30666851      PMCID: PMC6380996          DOI: 10.1631/jzus.B1800112

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  3 in total

1.  Ultramarine blue nanoparticles as a label for immunochromatographic on-site determination of ractopamine.

Authors:  Jing Liu; Qiongqiong Yu; Guangying Zhao; Wenchao Dou
Journal:  Mikrochim Acta       Date:  2020-04-23       Impact factor: 5.833

Review 2.  Paper-Based Fluidic Sensing Platforms for β-Adrenergic Agonist Residue Point-of-Care Testing.

Authors:  Hongzhi Luo; Shan Liu; Lina Shi; Zhu Li; Qianwen Bai; Xiaoxin Du; Lijun Wang; He Zha; Chenzhong Li
Journal:  Biosensors (Basel)       Date:  2022-07-12

Review 3.  Current Advances in Immunoassays for the Detection of β2-Agonists.

Authors:  Shuyu Ouyang; Shuting Yu; Yingying Le
Journal:  Foods       Date:  2022-03-11
  3 in total