Literature DB >> 30666681

Clinical Value of Shear Wave Elastography Added to Targeted Ultrasound (Second-Look Ultrasound) in the Evaluation of Breast Lesions Suspicious of Malignancy Detected on Magnetic Resonance Imaging.

Frederick Wing-Fai Au1, Sandeep Ghai2, Fang-I Lu3, Hua Lu4.   

Abstract

OBJECTIVES: To determine the value of shear wave elastography (SWE) added to targeted ultrasound (US) after breast magnetic resonance imaging (MRI).
METHODS: From July 2015 to October 2017, 40 patients who underwent targeted US evaluations of suspicious MRI-detected American College of Radiology Breast Imaging Reporting and Data System category 4 lesions (mass or nonmass enhancement) were enrolled in this prospective study. B-mode US and SWE examinations were performed to detect US correlates to MRI-detected lesions; their Breast Imaging Reporting and Data System categories were recorded; lesions that were dark blue on a 6-point color scale or had maximum elasticity of 30 kPa or less were categorized as soft. Biopsy was performed with US or MRI guidance, with the pathologic findings correlated with MRI, US, and SWE findings. The value of SWE for lesion detection and identification of benign lesions was determined.
RESULTS: The mean age of the 40 patients was 51.1 years. There were 48 MRI-detected lesions (20 cancers, 3 high-risk lesions, and 25 benign lesions). Ultrasound correlates (8 category 3 and 25 category 4) were shown for 33 lesions (69%; P < .0001), with 16 cancers (80%; P < .0001) and 17 benign lesions. Shear wave elastography assisted detection of 3 (19%) cancers on US imaging. All 7 soft US category 3 lesions were benign (7 of 33 [21%]; P = .0014).
CONCLUSIONS: Shear wave elastography was useful with targeted US after breast MRI to increase cancer detection by US. A significant number of US correlates to MRI-detected lesions could have been identified as benign (category 3 and soft) before biopsy, with the potential of short-interval follow-up of MRI-detected lesions with benign US correlates instead of biopsy.
© 2019 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  breast lesions; magnetic resonance imaging; shear wave elastography; ultrasound

Mesh:

Year:  2019        PMID: 30666681     DOI: 10.1002/jum.14936

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Stiffness in breast masses with posterior acoustic shadowing: significance of ultrasound real time shear wave elastography.

Authors:  Hui Luo; Jian Li; Yang Shi; Xiaojun Xiao; Yuanyang Wang; Zhanghong Wei; Jinfeng Xu
Journal:  BMC Med Imaging       Date:  2022-04-17       Impact factor: 2.795

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.