Literature DB >> 30662845

Evaluation of dynamic stereopsis in intermittent exotropia patients.

Jing Zhong1, Da-Ming Deng1, Zi-Dong Chen1, Jin-Rong Li1, Jun-Peng Yuan1, Lei Feng1, Ai-Hou Wang2,3, Min-Bin Yu1.   

Abstract

AIM: To delineate the characteristics of the dynamic stereopsis test and analyze related parameters in intermittent exotropia [X(T)] patients.
METHODS: Fifty-seven X(T) patients and 55 normal subjects were enrolled in this study. The normal and X(T) groups were used to test the reproducibility and reliability of the dynamic stereopsis test, and Bangerter filters with densities of 0.2 were then used to simulate suppression to test for traditional and dynamic stereopsis. In the X(T) group, the measurements included 1) dynamic stereopsis test comprising three parts: motion+disparity, motion only and disparity only; 2) ocular deviation angle; 3) Bagolini striated lens test; 4) disease course; and 5) Titmus stereopsis test.
RESULTS: The test-retest reliability of the dynamic stereopsis method was 0.901 in the normal and X(T) groups, and none of the X(T) patients were able to pass the static and dynamic stereopsis tests after using the 0.2 Bangerter filter. The accuracy rate was greater than 80% in the normal group and 31.81%, 36.36%, and 45.45% for the motion+disparity, motion-only and disparity-only components of the traditional test for X(T) patients diagnosed with stereoblindness via traditional tests, respectively. Patients with a long disease course (>1y) had worse dynamic stereopsis than those with a short disease course (<1y; P<0.05, Chi-square test). The deviation angle was not correlated with the motion+disparity, disparity-only, or the motion-only test components (all P>0.05, Chi-square test).
CONCLUSION: Dynamic stereopsis is preserved in certain X(T) patients diagnosed with stereoblindness via traditional tests. A long disease course was shown to be a negative factor for dynamic stereopsis in X(T) patients which might be associated with worse progression, and provide good references clinically.

Entities:  

Keywords:  disparity; intermittent exotropia; motion

Year:  2019        PMID: 30662845      PMCID: PMC6326943          DOI: 10.18240/ijo.2019.01.13

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  1 in total

1.  A novel dynamic random-dot stereopsis assessment to measure stereopsis in intermittent exotropia.

Authors:  Jing Zhong; Daming Deng; Zidong Chen; Jinrong Li; Junpeng Yuan; Lei Feng; Minbin Yu
Journal:  Ann Transl Med       Date:  2021-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.